Critical heat flux enhancement by means of liquid subcooling and centrifugal force induced by flow curvature
نویسندگان
چکیده
Experiments are performed to assess the feasibility of cooling high flux heat sources flush mounted on the inner wall of a cylindrical vessel by a dielectric liquid flowing at high velocity parallel to the vessel wall. Fluid motion is induced by rotating a stirrer having radial blades about the axis of the vessel. The study focusses on examining critical heat flux (CHF) enhancement attributed to liquid subcooling and the centrifugal body force induced by fluid rotation. This includes using test vessels with different inner radii, 4.19 and 7.62 cm, three heater lengths, 1.27,2.54 and 5.08 cm, and stirrers having two or four blades. CHF is found to be independent of heater length and the number of stirrer blades. CHF enhancement is achieved by increasing the liquid fill volume, increasing the rotational speed and/or decreasing the radius of curvature. The system facilitates the removal of heat at nearly isothermal wall conditions over a wide range of heat fluxes. A CHF correlation is presented which accounts for the effects of subcooling and centrifugal force over all conditions tested.
منابع مشابه
Enhancement of Critical Heat Flux From High Power Microelectronic Heat Sources in a Flow Channel
Several surface augmentation techniques were examined in an investigation of enhancement of critical heat flux (CHF) from a simulated electronic chip to a fluorocarbon (FC-72) liquid in a vertical channel. A parametric comparison of boiling performances is presented for a smooth surface and for surfaces with low-profile microgrooves, low-profile microstuds, and high-profile pin fins. Critical h...
متن کاملEffects of high subcooling on two-phase spray cooling and critical heat flux
Experiments were performed with FC-77 using three full-cone spray nozzles to assess the influence of subcooling on spray performance and critical heat flux (CHF) from a 1.0 1.0 cm test surface. The relatively high boiling point of FC-77 (97 C at one atmosphere) enabled testing at relatively high levels of subcooling. Increasing the subcooling delayed the onset of boiling but decreased the slope...
متن کاملSubcooled Pool Boiling Experiments on Horizontal Heaters Coated With Carbon Nanotubes
Pool boiling experiments were conducted with three horizontal, flat, silicon surfaces, two of which were coated with vertically aligned multiwalled carbon nanotubes (MWCNTs). The two wafers were coated with MWCNT of two different thicknesses: 9 m (Type-A) and 25 m (Type-B). Experiments were conducted for the nucleate boiling and film boiling regimes for saturated and subcooled conditions with l...
متن کاملExperimental Study on the Effect of Magnetic Field on Critical Heat Flux of Ferrofluid Flow Boiling in a Vertical Tube
In the present work, the critical heat flux measurements were performed for the subcooled flow boiling of pure water and magnetic nanofluids (i.e., water + 0.01 and 0.1 vol.% Fe3O4) in a vertical tube. The effect of applying an external magnetic field on the CHF variation was studied experimentally as well. The obtained results indicated that the subcooled flow boiling CHF in the vertical tub...
متن کاملNucleate Boiling and Critical Heat Flux From Protruded Chip Arrays During Flow Boiling
The effects of chip protrusion on the forced-convection boiling and critical heat flux (CHF) of a dielectric coolant (FC-72) were investigated. The multi-chip module used in the present study featured a linear array of nine, 10mm x 10 mm, simulated microelectronic chips which protruded 1 mm into a 20-mm wide side of a rectangular flow channel. Experiments were performed in vertical upflow with ...
متن کامل