Applanation pressure function in Goldmann tonometry and its correction.

نویسنده

  • Wiesław Śródka
چکیده

So far applanation tonometry has not worked out any theoretical basis for correcting the result of intraocular pressure measurement carried out on a cornea with noncalibration dimensions by means of the Goldmann tonometer. All the tables of instrument reading corrections for cornea thickness or cornea curvature radius are based exclusively on measurements. This paper represents an attempt at creating a mechanical description of corneal apex deformation in Goldmann applanation tonometry. The functional dependence between intraocular pressure and the pressure exerted on the corneal apex by the tonometer was determined from a biomechanical model. Numerical GAT simulations, in which this function was also interrelated with the cornea's curvature radius and thickness were run and a constitutive equation for applanation tonometry, i.e. a full analytical description of intraocular pressure as a function of the above variables, was derived on this basis. The correction factors were defined and an algorithm for correcting the measured pressure was formulated. The presented formalism puts the results of experimental tonometry in new light. Analytical correction factors need not to come exclusively from measurements. A geometric interdependence between them and their dependence on pressure have been revealed. The theoretical description of applanation tonometry contained in the constitutive equation consists of a pressure function developed for a cornea with calibration dimensions and a coefficient correcting this calibration function, dependent exclusively on the cornea's actual thickness and curvature radius. The calibration function is a generalization of the Imbert-Fick law.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery

BACKGROUND The purpose of this study was to determine the accuracy of intraocular pressure (IOP) measurement after laser in situ keratomileusis (LASIK) or epithelial laser in situ keratomileusis (Epi)-LASIK using Goldmann applanation tonometry, air puff tonometry, ocular response analyzer corneal compensated IOP (ORA IOPcc) and Pentacam corrected IOP. METHODS A prospective comparative clinica...

متن کامل

Pressure phosphene tonometry versus Goldmann applanation tonometry for measuring intraocular pressure before and after LASIK.

PURPOSE To compare pressure phosphene tonometry with Goldmann applanation tonometry for measuring intraocular pressure (IOP) before and after LASIK. METHODS Forty-three (18 men and 25 women) consecutive healthy patients underwent complete pre- and postoperative LASIK ophthalmologic assessments including manifest and cycloplegic refraction, keratometry, and central corneal thickness. Three rep...

متن کامل

Two-position measurement of intraocular pressure by PT100 noncontact tonometry in comparison with Goldmann tonometry

BACKGROUND The purpose of this study was to evaluate the precision of intraocular pressure measurements obtained by PT100 noncontact tonometry in a handheld and slit lamp-mounted position in comparison with that of Goldmann applanation tonometry in healthy young adults. METHODS Sixty eyes from 60 subjects (30 men and 30 women) aged 22 ± 1 (range 20-24) years participated in this study. Tripli...

متن کامل

Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.

BACKGROUND To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. DESIGN A prospective, cross-sectional study was conducted in a private tertiary glaucoma clinic. PARTICIPANTS OR SAMPLES One hundred nine (54 males : 55 females) patients includ...

متن کامل

Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods

PURPOSE To compare intraocular pressure (IOP) measurements, taken using Perkins applanation tonometry (PAT) and Goldmann applanation tonometry (GAT). METHODS 100 eyes of 100 patients underwent Perkins and Goldmann applanation tonometry, with a randomized order of modality, performed by a masked observer. The right eye was measured, for all subjects, and the data used in statistical analysis. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta of bioengineering and biomechanics

دوره 15 3  شماره 

صفحات  -

تاریخ انتشار 2013