Optimal Location and Control of Multi Hybrid Model Based Wind-Shunt FACTS to Enhance Power Quality

نویسنده

  • Belkacem Mahdad
چکیده

Modern power system becomes more complex and difficult to control with the wide integration of renewable energy and flexible ac transmission systems (FACTS). In recent years many types of renewable source (Wind, solar,) and FACTS devices (SVC, STATCOM, TCSC, UPFC) integrated widely in the electricity market. Wind power industry has been developing rapidly, and high penetration of wind power into grid is taking place, (Bent, 2006), (Mahdad.b et al., 2011). According to the Global Wind Energy Council, GWEC, 15.197 MW wind turbine has been installed in 2006 (Chen et al. 2008), in terms of economic value, the wind energy sector has now become one of the important players in the energy markets, with the total value of new generating equipment installed in 2006 reaching US 23 billion. FACTS philosophy was first introduced by (Hingorani, N.G., 1990), (Hingorani, N.G., 1999) from the Electric power research institute (EPRI) in the USA, although the power electronic controlled devices had been used in the transmission network for many years before that. The objective of FACTS devices is to bring a system under control and to transmit power as ordered by the control centers, it also allows increasing the usable transmission capacity to its thermal limits. With FACTS devices we can control the phase angle, the voltage magnitude at chosen buses and/ or line impedances. In practical installation and integration of renewable energy in power system with consideration of FACTS devices, there are five common requirements as follows (Mahdad. b et al., 2011): 1. What Kinds of renewable source and FACTS devices should be installed? 2. Where in the system should be placed? 3. How to estimate economically the number, optimal size of renewable source and FACTS to be installed in a practical network? 4. How to coordinate dynamically the interaction between multiple type renewable source, multi type of FACTS devices and the network to better exploit their performance to improve the reliability of the electrical power system? 5. How to review and adjust the system protection devices to assure service continuity and keep the indices power quality at the margin security limits? Optimal placement and sizing of different type of renewable energy in coordination with FACTS devices is a well researched subject which in recent years interests many expert

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Location and Parameter Settings of UPFC Device in Transmission System based on Imperialistic Competitive Algorithm

In this paper, we present a new method to determine the optimal location and parameter settings of UnifiedPower Flow Controller (UPFC) for removing voltage violations and transmission lines overloading. UPFC isconsidered as the most powerful member of the FACTS devices, that it can control shunt and series power flow.This option gives to UPFC the power to control the voltage profile and transmi...

متن کامل

Optimal Locating and Sizing of Unified Power Quality Conditioner- phase Angle Control for Reactive Power Compensation in Radial Distribution Network with Wind Generation

In this article, a multi-objective planning is demonstrated for reactive power compensation in radial distribution networks with wind generation via unified power quality conditioner (UPQC). UPQC model, based on phase angle control (PAC), is used. In presented method, optimal locating of UPQC-PAC is done by simultaneous minimizing of objective functions such as: grid power loss, percentage of n...

متن کامل

Combined Use of Sensitivity Analysis and Hybrid Wavelet-PSO- ANFIS to Improve Dynamic Performance of DFIG-Based Wind Generation

In the past few decades, increasing growth of wind power plants causes different problems for the power quality in the grid. Normal and transient impacts of these units on the power grid clearly indicate the need to improve the quality of the electricity generated by them in the design of such systems. Improving the efficiency of the large-scale wind system is dependent on the control parameter...

متن کامل

Determining the Optimal Strategy of Multi Virtual Power Plants using GA-GT

abstract: In the present work, determining the optimal strategy(profit based) of multi virtual power plants (VPPs) as well as the objective of maximizing profit through the multi-level control of VPPs are discussed by the micro-grid utilization center including virtual power plants. VPPs include renewable resources such as wind farms, photovoltaic, and conventional resources such as fuel cell, ...

متن کامل

Optimization of grid independent diesel-based hybrid system for power generation using improved particle swarm optimization algorithm

The power supply of remote sites and applications at minimal cost and with low emissions is an important issue when discussing future energy concepts. This paper presents modeling and optimization of a photovoltaic (PV)/wind/diesel system with batteries storage for electrification to an off-grid remote area located in Rafsanjan, Iran. For this location, different hybrid systems are studied and ...