The application of PET-CT to post-mastectomy regional radiation therapy using a deformable image registration

نویسندگان

  • Yu Sun Lee
  • Kyoung Ju Kim
  • Seung Do Ahn
  • Eun Kyung Choi
  • Jong Hoon Kim
  • Sang-wook Lee
  • Si Yeol Song
  • Sang Min Yoon
  • Young Seok Kim
  • Jin-hong Park
  • Byung Chul Cho
  • Su Ssan Kim
چکیده

BACKGROUND To evaluate the utility of the preoperative PET-CT using deformable image registration (DIR) in the treatment of patients with locally advanced breast cancer and to find appropriate radiotherapy technique for further adequate treatment of axillary nodal area. METHODS Sixty-five breast cancer patients who had level II, III axillary or supraclavicular lymph node metastasis on ¹⁸F-FDG PET-CT and received postoperative radiotherapy after modified radical mastectomy were enrolled. One radiation oncologist contoured normal organs (axillary vessels, clavicular head, coracoids process and humeral head) and involved lymph nodes on PET-CT and simulation CT slices. After contouring, deformable image registration of PET-CT on simulation CT was carried out. To evaluate the performance of the DIR, Dice similarity coefficient (DSC) and Center of mass (COM) were used. We created two plans, one was the historically designed three field plan and the other was the modified plan based on the location of axillary lymph node, and we compared the doses that irradiated the axillary lymph nodes. RESULTS The DSCs for axillary artery, axillary vein, clavicular head, coracoids process and humeral head were 0.43 ± 0.15, 0.39 ± 0.20, 0.85 ± 0.10, 0.72 ± 0.20 and 0.77 ± 0.20, respectively. The distances between the COMs of axillary artery, axillary vein, clavicular head, coracoids process and humeral head in simulation CT and from PET-CT were 13.0 ±7.1, 20.2 ± 11.2, 4.4 ± 6.3, 3.7 ± 6.7, and 9.5 ± 25.0 mm, respectively. In the historically designed plan, only 57.7% of level II lymph nodes received more than 95% of prescribed dose and the coverage was improved to 70.0% with the modified plan (p < 0.01). For level III lymph nodes, the volumes received more than 95% of prescribed dose were similar in both plans (96.8 % vs 97.9%, p = 0.35). CONCLUSION Deformable image registration of PET-CT on simulation CT was helpful in the identification of the location of the preoperatively involved axillary lymph node. Historically designed three-field plan was not adequate to treat the axillary level II lymph node area. Novel treatment technique based on the location of axillary lymph node from PET-CT using DIR can result in more adequate coverage of nodal area.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Registration of PET and CT images based on multiresolution gradient of mutual information demons algorithm for positioning esophageal cancer patients

Accurate registration of 18F-FDG PET (positron emission tomography) and CT (computed tomography) images has important clinical significance in radiation oncology. PET and CT images are acquired from (18)F-FDG PET/CT scanner, but the two acquisition processes are separate and take a long time. As a result, there are position errors in global and deformable errors in local caused by respiratory m...

متن کامل

Contribution of 68Ga-PSMA PET/CT to targeting volume delineation of prostate cancer treated with conformal radiation therapy: Which SUV threshold is appropriate?

Introduction: Prostate-specific membrane antigen (PSMA) has been demonstrated as a promising tool for specific imaging of prostate cancer (PCa) via positron emission tomography-computed tomography (PET/CT) scanning. Radiation treatment planning (RTP) based on 68Ga-PSMA PET/CT scanning can also lead to some decision modifications.  The specific goal o...

متن کامل

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

Evaluation of deformable image registration in HDR gynecological brachytherapy

Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...

متن کامل

A Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images

Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013