Improved continuous-flow (SMAC) determination of serum albumin.
نویسندگان
چکیده
The albumin values determined by the bromcresol green methods do not compare well with values by more specific methods for albumin determination. The discrepancies have been related to, among other things, acute-phase reactants and are especially pronounced in the lower albumin range. These disadvantages are also inherent in a routine continuous-flow method for albumin (SMAC). The bromcresol green method has been improved considerably by shortening the reaction time before the absorbance is measured, as is described here. The modified method yields values that better agree with those by more specific methods and an influence of acute-phase reactants is no longer observed.
منابع مشابه
The introduction of bromocresol purple for the determination of serum albumin on SMAC and ACA, and the standardization procedure.
The bromocresol purple methods for the determination of serum albumin on the Technicon SMAC and the DuPont ACA systems were evaluated and compared with the corresponding bromocresol green methods, a radial immunodiffusion (RID) and an electrophoresis technique. The linearity and precision of the dye binding methods were comparable. The bromocresol purple methods were more influenced by lipaemia...
متن کاملDetermination of serum aspartate aminotransferase with pyridoxal 5'-phosphate in the Technicon SMAC and Du Pont aca compared and correlated with the IFCC recommended method.
Inexpensive improvements in continuous-flow analytical apparatus can eliminate some perplexing inconsistencies and limitations in the use of the Technicon SMAC instrument for measuring the activity in serum of aspartate aminotransferase (EC 2.6.1.1) in the presence of pyridoxal 5'-phosphate. In addition, a calibration procedure based on values for this enzyme obtained by a modified IFCC method ...
متن کاملContinuous-flow serum albumin determination by reaction with picrate ions, with use of a flow-through picrate ion electrode.
An automated potentiometric method for serum albumin determination by use of the picrate/albumin reaction is described. A continuous-flow system and a specially designed flow-through picrate ion electrode were used in making the measurements. Various factors affecting the reaction, such as pH, picrate ion concentration, and reaction time, were studied. Peak height in millivolts and albumin conc...
متن کاملThe use of immobilized enzyme reactors in continuous-flow analyzers for the determination of glucose, urea, and uric acid.
We describe the use of immobilized enzymes in assay methods for the determination of glucose with glucose oxidase, uric acid with uricase, and urea with urease in serum samples. The enzyme reactor tubes were adapted to continuous-flow analyzers (Technicon AA II, SMA 12/60, and SMAC) used in routine laboratory determinations, and results with their use were compared to those from assays involvin...
متن کاملMeasurement of magnesium by continuous-flow colorimetry.
We describe the application to the Technicon SMAC system of a micellar-improved calmagite method for the measurement of magnesium. In this continuous-flow method a dialyzer is not needed, because protein interference is negligible. Sample interaction was estimated to be 3%. The increased sensitivity of the method allows for a small sample volume (37 microL/min). Results obtained agreed well wit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 24 7 شماره
صفحات -
تاریخ انتشار 1978