Circulatory assistance by intrathoracic pressure variations: optimization and mechanisms studied by a mathematical model in relation to experimental data.

نویسندگان

  • R Beyar
  • H R Halperin
  • J E Tsitlik
  • A D Guerci
  • D Kass
  • M L Weisfeldt
  • N C Chandra
چکیده

The hemodynamic effects of phasic variations in intrathoracic pressure (ITP) timed to the cardiac cycle were predicted by a mathematical model and were compared with data from canine experimental studies. The model was used to predict the hemodynamic effects of changing the onset of the ITP rise relative to the start of cardiac systole, as well as the hemodynamic effects of changes in the duration and amplitude of the ITP rise. The predictions of the model were compared with hemodynamic data from seven anesthetized dogs. Cardiac function was depressed with large doses of verapamil and propranolol, and the hearts were atrioventricular sequentially paced at a rate of 72 beats/min. Phasic ITP variations were generated by a perithoracic vest and were electronically timed to the cardiac cycle. The model predicted, and the experimental data confirmed, that phasic intrathoracic pressure variations generated by vest inflation, timed to the cardiac cycle, can augment both peak and mean aortic flow. The following predictions of the model were also confirmed by the experimental data: 1) Maximum flow augmentation occurs when the onset of the ITP rise is simultaneous with the onset of left ventricular isovolumic contraction, and the ITP rise has a duration of 400 msec. 2) The magnitude of the flow augmentation is a function of the amplitude of the ITP rise. The experimental data showed that there was little further flow augmentation when the ITP rise was greater than 30-40 mm Hg. 3) The magnitude of flow augmentation was inversely proportional to the peak left ventricular elastance (Emax). The best fit between the measured and predicted flow augmentations was obtained for an assumed Emax of 0.5 mm Hg/ml, while Emax measurements in three dogs, using a volume conductance catheter and transient vena caval occlusion, yielded values of 0.4-1.6 mm Hg/ml. Thus, both the mathematical model and canine experiments showed that relatively low-amplitude ITP variations, rising synchronously with the onset of cardiac systole and having an optimal duration, assist the failing heart by augmentation of aortic flow. The degree of cardiac assistance decreases if the ITP variations do not rise synchronously with the onset of systole, or if their duration is not optimal. Thus, properly applied ITP variations may be used as an efficient, noninvasive method to temporarily assist the failing heart.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Minimum Order Lumped-Parameter Model of Circulatory System for Patients with Suffered Left and Right-Sided Heart Failure

In this study a new minimum lumped electrical model of total circulatory system through numerical solutions to approximate the response of the human circulatory system was presented. Among five existent ventricular elastances as activity function of heart pumps, a more accurate model was chosen as well as the operation of baroreflex system to accommodate variations in heart rate and systemic va...

متن کامل

Determination of Minimum Miscibility Pressure in Gas Injection Process by Using ANN with Various Mixing Rules

Miscible gas injection is one of the most effective enhanced oil recovery techniques and minimum miscibility pressure (MMP) is an important parameter in miscible gas injection processes. The accurate determination of this parameter is critical for an adequate design of injection equipment investment prospect. The purpose of this paper is to develop a new universal artificial neural network (U-A...

متن کامل

A Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform

Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...

متن کامل

Experimental and Theoretical Investigation of Drying of Green Peas in a Fluidized Bed Dryer of Inert Particles Assisted by Infrared Heat Source

Drying of green peas in a Fluidized Bed Dryer (FBD) with inert particle, heated by combined sources of hot air and InfraRed (IR) radiation, has been experimentally and theoretically studied. For this purpose, an experimental set up was constructed. This setup was composed of a cylindrical bed dryer containing some inert particles which are fluidized by hot air. Some infrar...

متن کامل

A NEW APPROACH BASED ON FINITE ELEMENT MODEL UPDATING FOR STRUCTURAL DAMAGE IDENTIFICATION

In this study, the finite element model updating was simulated by reducing the stiffness of the members. Due to lack of access to the experimental results, the data obtained from an analytical model were used in the proposed structural damage scenarios. The updating parameters for the studied structures were defined as a reduction coefficient applied to the stiffness of the members. Parameter v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 64 4  شماره 

صفحات  -

تاریخ انتشار 1989