Analysis of Effects of Nonuniform Beam Profile on Doppler Power Spectrum and Mean Velocity
نویسندگان
چکیده
In this paper we present a detailed simulation method to estimate the accuracy of Doppler power spectrum and mean blood velocity, using real CW Doppler transducers with twin-crystal arrangement. The method is based on dividing the sample volume into small cells using the statistics of the total power of Doppler spectrum with the same Doppler shift frequency, and from total power, which predicts errors in the mean blood velocity. Results show that the Doppler angle, vessel depth, and sample volume length are not sensitive functions for both the Doppler power spectrum and error in the mean blood velocity. However vessel diameter, displacement distance and blood velocity profiles have significant effects. Finally, comparisons between simulation and experiment results illustrated a good agreement for parabolic flow profile. These results will contribute to an improved understanding of Doppler power spectrum and error in mean blood velocity in medical ultrasound diagnostics. Keywords-continuous-wave, semicircle transducer, Doppler power spectrum, blood velocity, spectral broadening
منابع مشابه
Normal Color and Pulsed-Waved Doppler Ultrasonography of Femoral and Axillary Arteries in Dogs
Objective- Obtaining the normal images ofcolor doppler and estimation ofblood flow velocity parametersof femoral and axillary arteries in dog.Design- Descriptive studyAnimals- 7 healthy adult mixed-breed dogs, weighing 14.3 ± 2.8 kg (mean ± SD).Proceudure- Left and right femoral and axillary arteries of hind and forelimbs were evaluated. Colorand spectral doppler images ofthe each artery were o...
متن کاملAnalyzing the Propagation Behavior of a Gaussian Laser Beam through Seawater and Comparing with Atmosphere
Study of the beam propagation behavior through oceanic media is a challenging subject. In this paper, based on generalized Collins integral, the mean irradiance profile of Gaussian laser beam propagation through ocean is investigated. Power In Special Bucket (PIB) is calculated. Using analytical expressions and calculating seawater transmission, the effects of absorption and scattering on beam ...
متن کاملEffects of along- and cross-radar-beam winds on Doppler radar spectrum
Beam broadening effects on the Doppler radar spectrum induced by alongand cross-radar-beam winds are theoretically investigated in this article. Analytical expression of beam broadening spectrum for a vertical beam subject to a constant vertical wind in the absence of horizontal wind is derived first. We find that the resultant beam broadening spectral shape is in an exponential form, rather th...
متن کاملPhase-Only Synthesis of Antenna Arrays Using Nonuniform Phased Sampling Method
Nonuniform Phased Sampling method is proposed to phase-only synthesize the power pattern of both linear and planar antenna arrays. This method modifies the conventional sampling method which is used for amplitude-phase synthesis. This method is based on assigning suitable phases to the sampling points of radiation pattern in order to reach desired amplitude of currents. Some examples are given ...
متن کاملResults of Transcranial Doppler in Children with Sickle Cell Disease: Correlation between the Time-Averaged Mean of Maximum Velocity and Some Hematological Characteristics
Abstract Background: Transcranial Doppler ultrasonography results have not been previously studied in among Iranian sickle cell anemia patients. The present study was performed to evaluate the pattern of intracranial flow velocities among Iranian children with sickle cell anemia and the hematological parameters that can affect the time-averaged mean of maximum velocity in major intracranial...