Lymphatic function measurements influenced by contrast agent volume and body position.
نویسندگان
چکیده
Several imaging modalities have been used to assess lymphatic function, including fluorescence microscopy, near-infrared fluorescence (NIRF) imaging, and Doppler optical coherence tomography (DOCT). They vary in how the mouse is positioned, the invasiveness of the experimental setup, and the volume of contrast agent injected. Here, we present how each of these experimental parameters affects functional measurements of collecting lymphatic vessels. First, fluorescence microscopy showed that supine mice have a statistically lower contraction frequency compared with mice sitting upright. To assess the effect of different injection volumes on these endpoints, mice were injected with 4, 10, or 20 μl of dye. The lowest frequencies were observed after 20-μl injections. Interestingly, lymph-flow DOCT revealed that although there was lower contraction frequency in mice injected with 20 μl versus 4 μl, mice showed a higher volumetric flow with a 20-μl injection. This indicates that contraction frequency alone is not sufficient to understand lymphatic transport. Finally, NIRF revealed that removing the skin reduced contraction frequency. Therefore, this study reveals how sensitive these techniques are to mouse position, removal of skin, and dye volume. Care should be taken when comparing results obtained under different experimental conditions.
منابع مشابه
Overexpression of vascular endothelial growth factor 165 drives peritumor interstitial convection and induces lymphatic drain: magnetic resonance imaging, confocal microscopy, and histological tracking of triple-labeled albumin.
Increased expression of vascular endothelial growth factor (VEGF) has been associated with increased lymph node metastases. The aim of this work was to determine whether VEGF-induced hyperpermeability affects peritumor interstitial convection and lymphatic drain, thus linking this growth factor with lymphatic function. Noninvasive imaging of lymphatic function induced by vascular hyperpermeabil...
متن کاملAssessment of Contrast Media Volume Injected and Image Contrast in Abdominal Pelvic CT Scan and Related Factors in Referral Hospitals in Mazandaran, Iran
Background and purpose: Computed tomography scan (CT) is highly capable of diagnosing abdominal and pelvic lesions. Injection of contrast media at appropriate concentration and volume provides the least side effects and the highest image quality. This study aimed at investigating the volume of contrast medium injected and the level of image contrast compared to the standard model, in the imagi...
متن کاملEffect of postural changes, nitroglycerin and verapamil on diastolic ventricular function as determined by radionuclide angiography in normal subjects.
Whereas improvement in diastolic function indexes in response to therapeutic interventions has been attributed to a beneficial effect of the intervention, measurements of diastolic function appear to be influenced by changes in loading conditions, heart rate and sympathetic tone. To determine the effect of body position and short-term pharmacologic intervention on radionuclide angiographically ...
متن کاملDynamic imaging of lymphatic vessels and lymph nodes using a bimodal nanoparticulate contrast agent.
BACKGROUND Evaluation of lymphedema and lymph node metastasis in humans has relied primarily on invasive or radioactive modalities. While noninvasive technologies such as magnetic resonance imaging (MRI) offer the potential for true three-dimensional imaging of lymphatic structures, invasive modalities, such as optical fluorescence microscopy, provide higher resolution and clearer delineation o...
متن کاملPotential positive MRI contrast agent based on PVP-grafted superparamagnetic iron oxide nanoparticles with various repetition times
Objective(s): The present study aimed to evaluate the capability of synthesized and modified superparamagnetic iron oxide nanoparticles (SPIONs) as the positive contrast agent in magnetic resonance imaging (MRI) by investigating the effect of repetition time (TR) on the MRI signal intensity. Materials and Methods: SPIONs were synthesized using the co-precipitation method, and their surfac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JCI insight
دوره 3 2 شماره
صفحات -
تاریخ انتشار 2018