Determination ofmass transfer coefficients for packingmaterials used in biofilters and biotrickling filters for air pollution control—2: Development of mass transfer coefficients correlations
نویسندگان
چکیده
Correlations that allow determination of gas film mass transfer coefficients (kGat , kGaw) and liquid film mass transfer coefficients (kLaw) for packing materials used in biofilters and biotrickling filters for air pollution control are presented. Lava rock, polyurethane foam cubes (PUF), Pall rings, porous ceramic beads, porous ceramic Raschig rings, and various compost–woodchips mixtures were used as packing materials. The functionality of gas and liquid velocity on mass transfer coefficients (kGat , kGaw, kLaw) obtained experimentally (see Part 1 of this paper) was correlated using modified Onda-type equations. The correlation equations helped to better understand the sensitivity of gas and liquid velocities on mass transfer, and the effects of packing wetting. Each packing had a different functionality with gas and liquid velocity and different wetting property, hence different correlation equations were needed for the different packing materials. Most of the fitted data fell within ±20% of the experimental values. 2007 Elsevier Ltd. All rights reserved.
منابع مشابه
Determination ofmass transfer coefficients for packingmaterials used in biofilters and biotrickling filters for air pollution control. 1. Experimental results
Gas film mass transfer coefficients (kGat , kGaw) and liquid film mass transfer coefficients (kLaw) for packing materials used in biofilters and biotrickling filters for air pollution control were determined experimentally. Lava rock, polyurethane foam cube (PUF), Pall ring, porous ceramic beads, porous ceramic Raschig rings and compost–woodchips mixtures were investigated. The experiments were...
متن کاملThe Overall Heat Transfer Characteristics of a Double Pipe Heat Exchanger: Comparison of Experimental Data with Predictions of Standard Correlations
The single-phase flow and thermal performance of a double pipe heat exchanger are examined by experimental methods. The working fluid is water at atmospheric pressure. Temperature measurements at the inlet and outlet of the two streams and also at an intermediate point half way between the inlet and outlet is made, using copper-constantan thermocouple wires. Mass flow rates for each stream are ...
متن کاملInnovative Experimental Setup for the Parallel Operation of Multiple Bench Scale Biotrickling Filters for Waste Air Treatment
A new concept of periodically rotating biotrickling filters was developed for parallel operation of multiple bench scale biotrickling filters without the requirement for expensive equipment such as liquid recycle pumps and air flow regulation. The performance of 20 identically operated rotating biotrickling filters was reproducible with an average toluene elimination capacity of 79.4 g m h (sta...
متن کاملTurbulent Events and Gas-Side Mass Transfer Coefficients in a Wavy Air-Water Stratified Flow
Turbulence structure on the gas side of a wavy stratified flow was experimentally investigated in a near horizontal 18.7 cm (H) 10 cm (W) 5.5m (L) rectangular duct.By applying the Variable Interval Time Averaging (VITA) technique to the hot wire anemometer measurements frequency of occurrence of turbulent events were detected near the air-water interface. Experimental results showed that fr...
متن کاملComparison of Different Loop Bioreactors Based on Hydrodynamic Characteristics, Mass Transfer, Energy Consumption and Biomass Production from Natural Gas
The performance of a forced-liquid Vertical Tubular Loop Bioreactor (VTLB), a forced-liquid Horizontal Tubular Loop Bioreactor (HTLB) and a gas-induced External Airlift Loop Bioreactor (EALB) were compared for production of biomass from natural gas. Hydrodynamic characteristics and mass transfer coefficients were determined as functions of design parameters, physical properties of gases as ...
متن کامل