The paper discusses optimal operation of a general heat exchanger network with given structure, heat exchanger areas and stream data including predefined disturbances. A formulation of the steady state optimization problem is developed, which is easily adapted to any heat exchanger network. Using this model periodically for optimization, the operating conditions that minimize utility cost are found. Setpoints are constant from one optimization to the next, and for implementing the optimal solution special attention is paid to the selection of controlled variables such that the operation is insensitive to uncertainties (unknown disturbances and model errors). This is the idea of self-optimizing control. In addition to heat exchanger networks, the proposed method may also be applied to other processes where the optimum lies at the intersection of constraints. © 1999 Elsevier Science Ltd. All rights reserved.
منابع مشابه
Control structure design for optimal operation of heat exchanger networks
When only single bypasses and utility duties are used as manipulations, optimal operation of heat exchanger networks (HENs) can be categorized as an active constraint control problem. This work suggests a simple split-range control scheme to implement the optimal operation. The control structure can be found by solving an integer-linear programming (ILP) problem with two objective functions pro...
متن کاملA Simple Strategy for Optimal Operation of Heat Exchanger Networks
The objective of this work is to propose a systematic procedure to find a control structure for optimal operation of heat exchanger networks. Optimal operation in this context requires that 1) all controlled temperatures are kept at their targets and 2) utility cost is minimized. The degrees of freedom of heat exchanger networks are analyzed and used to identify if the operation is structurally...
متن کاملOptimal operation of heat exchanger networks with stream split: Only temperature measurements are required
For heat exchanger networks with stream splits, we present a simple way of controlling the split ratio. We introduce the “Jäschke Temperature”, which for a branch with one exchanger is defined as TJ = (T − T0)/(Th − T0), where T0 and T are the inlet and outlet temperatures of the split stream (usually cold), and Th is the inlet temperature of the other stream (usually hot). Assuming the heat tr...
متن کاملA Simple Control Scheme for Near-optimal Operation of Parallel Heat Exchanger Systems
For heat exchanger networks with stream splits, we present a simple way of controlling the split ratio. We introduce the ”Jäschke Temperature”, which for a branch with one exchanger is defined as TJ = (T−T0) Th−T0 , where T0 and T are the inlet and outlet temperatures of the split stream (usually cold), and Th is the inlet temperature of the other stream (usually hot). Assuming the heat transfe...
متن کاملOperational Controllability of Heat Exchanger Networks
Process integration is motivated from economic benefits, but it also impacts on the plant behavior introducing interactions and in many cases making the process more difficult to control and operate. During the operation utility flow rates and bypasses are widely used for effective control of process stream target temperatures, but the number of utility units is usually less than the number of ...
متن کامل