OCT-based elastography for large and small deformations.
نویسندگان
چکیده
We present two approaches to speckle tracking for optical coherence tomography (OCT)-based elastography, one appropriate for small speckle motions and the other for large, rapid speckle motions. Both approaches have certain advantages over traditional cross-correlation based motion algorithms. We apply our algorithms to quantifying the strain response of a mechanically inhomogeneous, bi-layered polyvinyl alcohol tissue phantom that is subjected to either small or large dynamic compressive forces while being imaged with a spectral domain OCT system. In both the small and large deformation scenarios, the algorithms performed well, clearly identifying the two mechanically disparate regions of the phantom. The stiffness ratio between the two regions was estimated to be the same for the two scenarios and both estimates agreed with the expected stiffness ratio based on earlier mechanical testing. No single numerical approach is appropriate for all cases and the experimental conditions dictate the proper choice of speckle shift algorithm for OCT-based elastography studies.
منابع مشابه
A Modification on Applied Element Method for Linear Analysis of Structures in the Range of Small and Large Deformations Based on Energy Concept
In this paper, the formulation of a modified applied element method for linear analysis of structures in the range of small and large deformations is expressed. To calculate deformations in the structure, the minimum total potential energy principle is used. This method estimates the linear behavior of the structure in the range of small and large deformations, with a very good accuracy and low...
متن کاملCorrelation-stability approach to elasticity mapping in OCT: comparison with displacement-based mapping and \textit{in vivo} demonstrations
A variant of compression optical coherence elastography for mapping relative tissue stiffness is reported. Unlike conventionally discussed displacement-based (DB) elastorgaphy, in which the decrease in the cross-correlation is a negative factor causing errors in mapping displacement and strain fields, we propose to intentionally use the difference in the correlation stability (CS) for deformed ...
متن کاملOCT elastography: imaging microscopic deformation and strain of tissue.
Optical coherence tomography (OCT) has been applied to the study of the microscopic deformation of biological tissue under compressive stress. We describe the hardware and theory of operation of an OCT elastography system that measures internal displacements as small as a few micrometers by using 2D cross-correlation speckle tracking. Results obtained from gelatin scattering models, pork meat, ...
متن کاملEndoscopic Optical Coherence Elastography Using Acoustic Radiation Force and Bending Vibration of Optical Fiber
Optical coherence tomography (OCT) is an optical imaging technique that provides high-resolution cross-sectional image for clinical and biological field, and the OCT systems have a depth resolution of less than 10 m. Recently, measurement of hardness using endoscopic OCT is required . Fig. 1 Basic configuration of the endoscopic OCT-based elastography using the focusing transducer and bending v...
متن کاملOCT-based arterial elastography: robust estimation exploiting tissue biomechanics.
We present a novel multi-resolution variational framework for vascular optical coherence elastography (OCE). This method exploits prior information about arterial wall biomechanics to produce robust estimates of tissue velocity and strain, reducing the sensitivity of conventional tracking methods to both noise- and strain-induced signal decorrelation. The velocity and strain estimation performa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 14 24 شماره
صفحات -
تاریخ انتشار 2006