Serum or Saliva Extraction of Toxic Compounds from Methyl Methacrylate Dental Materials and HPLC Analysis Combined with SPE
ثبت نشده
چکیده
Methyl methacrylate polymer (PolyMMA) is widely used as the composite resin for the dental plate. During the preparation process of PolyMMA by the polymerization reaction, benzoylperoxide (BPO) and N,N’-dimethylp-toluidine (DMPT) are added as the initiator and the stimulator, respectively. These compounds exhibit toxicity as well as a residue potential, their use raises concerns regarding human safety. The degree of elution into serum or saliva was determined to evaluate risk to the user. Analysis was by HPLC combined with solid-phase extraction using a C-18 column. The eluted compounds were found to be in the order of 10 to 70 ppm. *Corresponding author: Shintani H, Faculty of Science and Engineering, Chuo University, 1-13-27, Kasuga, Bunkyo, 112-8551, Tokyo, Japan, Tel: +81425922336; Fax: +81425922336; E-mail: [email protected] Received June 07, 2014; Accepted June 23, 2014; Published June 28, 2014 Citation: Shintani H (2014) Serum or Saliva Extraction of Toxic Compounds from Methyl Methacrylate Dental Materials and HPLC Analysis Combined with SPE. Pharmaceut Reg Affairs 3: 123. doi:10.4172/2167-7689.1000123 Copyright: © 2014 Shintani H. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
منابع مشابه
The Release of Residual Monomeric Methyl Methacrylate in Human Saliva after Using Acrylic Dentures
The Release of Residual Monomeric Methyl Methacrylate in Human Saliva after Using Acrylic Dentures Dr. AH. Alehavaz* - Dr. D. Qujeq** - Dr. A. Babapour*** *- Assistant Professor of Prosthodontics Dept. – Faculty of Dentistry – Babol University of Medical Sciences. **- Associate Professor of Biochemistry and Biophysics Dept. – Babol University of Medical Sciences. ***- Dentist. Background and Ai...
متن کاملDevelopment a HPLC method for simultaneous determination of Azinphose methyl, Diazinon, Phosalone and Chlorpyrifos residues in fruit
A high-performance liquid chromatography with ultraviolet detection (HPLC/UV) methodwhich was used solid-phase extraction for cleanup, was developed for the determination ofAzinphos methyl ,Phosalone, Diazinon and Chlorpyrifos residues in fruits. A full factorialexperimental design was used for development of HPLC condition and evaluation of effect ofthree factors (pH of mobile phase, percent o...
متن کاملDetermination of Some Polycyclic Aromatic Hydrocarbons in the Caspian Seawater by HPLC Following Preconcentration with Solid-Phase Extraction
A solid-phase extraction (SPE) method for sample clean-up and preconcentration followed by reversed-phase high-performance liquid chromatography (RP-HPLC) with uv detection is reported for determination of polycyclic aromatic hydrocarbons (PAHs) in the caspian seawater. A good resolution was obtained using acetonitrile:water (40:60) as mobile-phase for separation of these compounds. The eff...
متن کاملSPE-HPLC purification of endocrine-disrupting compounds from human serum for assessment of xenoestrogenic activity.
Assessment of xenoestrogenic activity in human serum samples requires the removal of endogenous sex hormones to assure that the activity measured originates from xenobiotic compounds only. Serum samples representing high, medium and lower accumulation of persistent organic pollutants (POPs) were extracted using solid-phase extraction (SPE) followed by normal-phase high-performance liquid chroma...
متن کاملDetection and quantification of monomers in unstimulated whole saliva after treatment with resin-based composite fillings in vivo.
Resin-based dental restorative materials contain allergenic methacrylate monomers, which may be released into saliva after restorative treatment. Monomers from resin-based composite materials have been demonstrated in saliva in vitro; however, studies analyzing saliva after restorative therapy are scarce. The aim of this study was to quantify methacrylate monomers in saliva after treatment with...