Apparatus for Neutron Scattering Measurements on Sheared Fluids
نویسنده
چکیده
We report on the construction of an apparatus to allow neutron scattering measurements on fluids undergoing shear. The apparatus has been used with the cold neutron small-angle-neutron-scattering (SANS) spectrometer at the NIST research reactor and will be made available to users as a permanent part of the NIST facility.
منابع مشابه
Apparatus for the investigation of liquid systems in a shear gradient by small angle neutron scattering (SANS)
2014 A Couette-type apparatus has been constructed which allows the observation of small angle neutron scattering from fluids in a constant shear gradient. Typical systems which can be investigated by this apparatus are polymer solutions and melts, anisotropic biopolymers, viruses in solution and various colloidal liquids. Revue Phys. Appl.19 (1984) 759-763 SEPTEMBRE 1984,
متن کاملابررساناهای دمای بالا- با دید نوترونها
Neutron scattering is proved to be a vital probe in unveiling the magnetic properties of high temperature superconductors (HTSC). Detailed information about the energy and momentum dependence of the magnetic dynamics of HTSC have been obtained directly by this technique. Over the past decade by improving the crystal growth methods, large and high quality single crystals of HTSC, which are ess...
متن کاملBrillouin and Umklapp scattering in polybutadiene: comparison of neutron and x-ray scattering.
We report a comparison of high resolution inelastic x-ray Brillouin scattering to coherent inelastic neutron scattering for amorphous deuterated polybutadiene, done for one temperature in the glass phase and another one in the melt. The x-ray scattering proves to be by far the better technique for such a polymer within its present resolution bounds. The neutron scattering allows one to extend t...
متن کاملDoppler shift anisotropy in small angle neutron scattering.
The two-dimensional patterns in our small angle neutron scattering (SANS) experiments from rapidly moving aerosols are anisotropic. To test the kinematic theory of two-body scattering that describes the anisotropy, we conducted SANS experiments using a constant source of D2O aerosol with droplets moving at approximately 440 m/s, and varied the neutron velocity from 267 to 800 m/s. The theoretic...
متن کاملCalibration of Neutron Measuring Devices in Differently Sized Rooms with Different-Structural Irradiation Apparatuses
The practical calibration rooms for neutron measuring devices are relatively small, where a large amount of room-reflected neutrons arise. Moreover the different structures of neutron irradiation apparatus influence the neutron spectrum and reference dose considerably. Therefore the influence of the neutron scattering was investigated in the three calibration rooms in different sizes and instal...
متن کامل