Calibration of the second-generation LIGO interferometric gravitationalwave detectors employs a method that uses injected periodic modulations to track and compensate for slow temporal variations in the differential length response of the instruments. These detectors utilize feedback control loops to maintain resonance conditions by suppressing differential arm length variations. We describe how the sensing and actuation functions of these servo loops are parameterized and how the slow variations in these parameters are quantified using the injected modulations. We report the results of applying this method to the LIGO detectors and show that it significantly reduces systematic errors in their calibrated outputs. PACS numbers: 04.80.Nn, 95.55.Ym, 42.62.-b
منابع مشابه
Development of a DMT monitor for tracking slow non- stationarities present in LIGO science data
Presence of slow non-stationarities has been seen in a series of studies with LIGO engineering and science data. It is important to track these slow variations or ‘drifts’ to diagnose their origin and correct them, as nonstationary data can affect sensitivity of astrophysical searches. A DMT (Data Monitoring Tool) monitor has been built to track slow non-stationarities in LIGO data. The monitor...
متن کاملImproving the Performance of ICA Algorithm for fMRI Simulated Data Analysis Using Temporal and Spatial Filters in the Preprocessing Phase
Introduction: The accuracy of analyzing Functional MRI (fMRI) data is usually decreases in the presence of noise and artifact sources. A common solution in for analyzing fMRI data having high noise is to use suitable preprocessing methods with the aim of data denoising. Some effects of preprocessing methods on the parametric methods such as general linear model (GLM) have previously been evalua...
متن کاملPrecise calibration of LIGO test mass actuators using photon radiation pressure
Precise calibration of kilometer-scale interferometric gravitational wave detectors is crucial for source localization and waveform reconstruction. A technique that uses the radiation pressure of a power-modulated auxiliary laser to induce calibrated displacements of one of the ∼10 kg arm cavity mirrors, a so-called photon calibrator, has been demonstrated previously and has recently been imple...
متن کاملA Study towards Improving Eye Tracking Calibration Technique Using Support Vector Regression
Visual attention and movement have evolved by many ways in eye tracking system. With the mechanism and functionality of eye movement, tracking human eye with high accuracy is possible. In eye tracking system, calibration technique can be considered as the first crucial step to be taken before eye can be tracked. The technique highly depends on a number of calibration points used and the selecti...
متن کاملImproving the Tracking Error Signal Extraction in IR Seeker with Stationary Wagon Wheel Reticle over all Field of View
The accuracy of target position detection in IR seeker depends on the accuracy of tracking error signal (TES) extraction from seeker Field of View (FOV). The type of reticle inside the seeker determines the output modulation signal that carries the TES. In this paper, the stationary wagon wheel reticle is used, which makes the type of the output signal as FM modulation in the linear region of F...
متن کامل