A comparison of kinematics and performance measures of two rowing ergometers.
نویسندگان
چکیده
Rowing injuries have been attributed to poor technique, suggesting a need to understand the mechanics of rowing and the influence on technique of different training regimes and ergometers. The aims of this study were to investigate the repeatability of the kinematics of the lumbopelvic region during rowing and to compare these kinematics between rowing on two different ergometers. An electromagnetic motion measuring device in conjunction with a load cell was used to determine the ergometer rowing kinematics of 12 rowers. Subjects were tested on three occasions at two different stroke rates, with an interval of one week between testing. Two datasets were obtained for the Concept II, to establish the repeatability of the kinematics, and one for the WaterRower. Bland and Altman's mean difference technique was used to test for consistency of technique, and the difference between ergometers was assessed using Students' paired T-tests. The kinematic measures of the lumbo pelvic region during rowing demonstrated high repeatability. The two ergometers showed a similarity in force profiles but some significant differences in rowing kinematics. There was greater rotation of the thigh segment in the sagittal plane throughout the stroke on the WaterRower (p < 0.01). There were also trends indicating that rotation of the pelvis in the sagittal plane was different between the two ergometers, for example on the Concept the mean angle of the pelvis at the catch was 5.4° and on the WaterRower it was 2.4° (p < 0.05). Measurement of lumbopelvic kinematics during rowing on a Concept II ergometer is repeatable. However, rowing kinematics varies between ergometers. Because a full analysis comparing rowing kinematics on water with rowing ergometers has not been made in this study, no conclusions regarding which ergometer simulates rowing on water can be made. The implications of the effect of these differences in technique requires further investigation. Key PointsMeasurement of lumbopelvic kinematics during rowing on a Concept II ergometer is repeatable.Rowing kinematics varies between the WaterRower and Concept II.
منابع مشابه
Rowing Crew Coordination Dynamics at Increasing Stroke Rates
In rowing, perfect synchronisation is important for optimal performance of a crew. Remarkably, a recent study on ergometers demonstrated that antiphase crew coordination might be mechanically more efficient by reducing the power lost to within-cycle velocity fluctuations of the boat. However, coupled oscillator dynamics predict the stability of the coordination to decrease with increasing strok...
متن کاملDon’t Rock the Boat: How Antiphase Crew Coordination Affects Rowing
It is generally accepted that crew rowing requires perfect synchronization between the movements of the rowers. However, a long-standing and somewhat counterintuitive idea is that out-of-phase crew rowing might have benefits over in-phase (i.e., synchronous) rowing. In synchronous rowing, 5 to 6% of the power produced by the rower(s) is lost to velocity fluctuations of the shell within each row...
متن کاملMuscle Synergy of Collegiate Rowers During 6 Min Maximal Rowing on Fixed and Slides Ergometer
The purpose of this study was to evaluate the muscle synergy of collegiate rowers during 6 min maximal rowing on different stretcher mechanisms: fixed (FE) and slides ergometer (SE). The association of muscle synergy to rowing economy and physiological variables was further quantify by statistical analysis. Method: Ten collegiate rowers were recruited at the end of their competitive season. Mus...
متن کاملReliability of power output during rowing changes with ergometer type and race distance.
Coaches, sport scientists and researchers assess rowing performance on-water and on a variety of ergometers. Ergometers are frequently used because of the easier assessment environment. However, there is limited information on the ability of rowers to reproduce mean power or time-trial time when using different rowing ergometers (Concept II and RowPerfect) or completing tests over different dis...
متن کاملA comparison of physiological responses to rowing on friction-loaded and air-braked ergometers.
The physiological responses of 10 trained rowers to a progressive incremental rowing protocol to exhaustion were investigated on Gjessing, Rowperfect fixed-mechanism and Rowperfect free-mechanism rowing ergometers. Heart rate, oxygen uptake (VO2), ventilation (VE) and blood lactate were determined at matched power values for each ergometer. The mean power and heart rate at the lactate anaerobic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of sports science & medicine
دوره 5 1 شماره
صفحات -
تاریخ انتشار 2006