Comparison of vascular closure devices vs manual compression after femoral artery puncture: the ISAR-CLOSURE randomized clinical trial.
نویسندگان
چکیده
IMPORTANCE The role of vascular closure devices (VCD) for the achievement of hemostasis in patients undergoing transfemoral coronary angiography remains controversial. OBJECTIVE To compare outcomes with the use of 2 hemostasis strategies after diagnostic coronary angiography performed via transfemoral access-a VCD-based strategy with 2 types of devices, an intravascular device and an extravascular device, vs standard manual compression. The primary hypothesis to be tested was that femoral hemostasis achieved through VCD is noninferior to manual compression in terms of vascular access-site complications. A secondary objective was the comparison of the 2 types of VCD. DESIGN, SETTING, AND PARTICIPANTS Randomized, large-scale, multicenter, open-label clinical trial. We enrolled 4524 patients undergoing coronary angiography with a 6 French sheath via the common femoral artery from April 2011 through May 2014 in 4 centers in Germany. Last 30-day follow-up was performed in July 2014. INTERVENTIONS After angiography of the access site, patients were randomized to hemostasis with an intravascular VCD, extravascular VCD, or manual compression in a 1:1:1 ratio. MAIN OUTCOMES AND MEASURES Primary end point: the composite of access site-related vascular complications at 30 days after randomization with a 2% noninferiority margin. Secondary end points: time to hemostasis, repeat manual compression, and VCD failure. An α-level of .025 was chosen for primary and secondary comparisons. RESULTS Of the 4524 enrolled patients, 3015 were randomly assigned to a VCD group (1509 received intravascular VCD and 1506 received extravascular VCD) and 1509 patients were randomly assigned to the manual compression group. Before hospital discharge, duplex sonography of the access site was performed in 4231 (94%) patients. The primary end point was observed in 208 patients (6.9%) assigned to receive a VCD and 119 patients (7.9%) assigned to manual compression (difference, -1.0% [1-sided 97.5% CI, 0.7%]; P for noninferiority<.001). Time to hemostasis was significantly shorter in patients with VCD (1 minute [interquartile range {IQR}, 0.5-2.0]), vs manual compression (10 minutes [IQR, 10-15]; P < .001). Time to hemostasis was significantly shorter among patients with intravascular VCD (0.5 minute [IQR, 0.2-1.0]), vs extravascular VCD (2.0 minutes [IQR, 1.0-2.0]; P <.001) and closure device failure was also significantly lower among those with intravascular vs extravascular VCD (80 patients [5.3%], vs 184 patients [12.2%]; P < .001). CONCLUSIONS AND RELEVANCE In patients undergoing transfemoral coronary angiography, VCDs were noninferior to manual compression in terms of vascular access-site complications and reduced time to hemostasis. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT01389375.
منابع مشابه
Clinical and Subclinical Femoral Vascular Complications after Deployment of two Different Vascular Closure Devices or Manual Compression in the Setting of Coronary Intervention.
BACKGROUND In the past two decades vascular closure devices (VCD) have been increasingly utilized as an alternative to manual compression after percutaneous femoral artery access. However, there is a lack of data confirming a significant reduction of vascular complication in a routine interventional setting. Systematic assessment of puncture sites with ultrasound was hardly performed. METHODS...
متن کاملFemoral artery closure after cardiac catheterization.
After diagnostic and interventional cardiac catheterization, femoral artery closure devices offer quicker time to hemostasis, ambulation, and discharge than does manual compression. Nurses should understand how femoral artery closure devices work, the potential vascular complications that may occur with their use, and the recommended time to ambulation and discharge.
متن کاملVascular closure devices: the second decade.
Vascular closure devices (VCDs) introduce a novel means for improving patient comfort and accelerating ambulation after invasive cardiovascular procedures performed via femoral arterial access. Vascular closure devices have provided simple, rapid, and reliable hemostasis in a variety of clinical settings. Despite more than a decade of development, however, VCD utilization has neither been routi...
متن کاملComplications of a percutaneous suture-mediated closure device versus manual compression for arteriotomy closure: a case-controlled study.
PURPOSE To evaluate the incidence and types of complications encountered with use of a percutaneous suture-mediated closure device versus manual compression for arteriotomy closure in a retrospective case-controlled study. MATERIALS AND METHODS The authors identified 100 consecutive patients, 15 men and 85 women 21-85 years of age (mean, 50 years), between December 2000 and July 2001 in whom ...
متن کاملMeta-analysis of randomized trials on the efficacy of vascular closure devices after diagnostic angiography and angioplasty.
BACKGROUND The aim of this meta-analysis was to evaluate the safety and efficacy of vascular closure devices (VCDs). METHODS This meta-analysis was performed in accordance with the Cochrane Handbook for Systematic Reviews. RESULTS The literature search yielded 31 prospective, randomized studies including 7,528 patients who were randomized to VCDs or manual/mechanical compression after diagn...