C-Arm Flat Detector CT Parenchymal Blood Volume Thresholds for Identification of Infarcted Parenchyma in the Neurointerventional Suite.
نویسندگان
چکیده
BACKGROUND AND PURPOSE C-arm flat detector CT parenchymal blood volume imaging allows functional assessment of the brain parenchyma in the neurointerventional suite. This study aimed to determine the optimal C-arm flat detector CT parenchymal blood volume thresholds for demarcating irreversibly infarcted brain parenchyma by using areas of restricted diffusion on MR imaging as a surrogate marker for infarction. MATERIALS AND METHODS Twenty-six patients with delayed cerebral ischemia following aneurysmal SAH underwent research C-arm CT parenchymal blood volume scans by using a biplane angiography system and contemporaneous MR imaging. Infarct and peri-infarct tissue VOIs and their homologous VOIs in the contralateral uninvolved hemisphere were delineated on the basis of the review of DWI, PWI, and ADC images. Voxel-based receiver operating characteristic curve analysis was performed to estimate the optimal absolute and normalized parenchymal blood volume values for demarcating the infarct voxels. RESULTS For 12 patients with areas of restricted diffusion (infarct volume, 6.38 ± 7.09 mL; peri-infarct tissue volume, 22.89 ± 21.76 mL) based on the voxel-based receiver operating characteristic curve analysis, optimal absolute and normalized parenchymal blood volume thresholds for infarction were 2.49 mL/100 g (area under curve, 0.76; sensitivity, 0.69; specificity, 0.71) and 0.67 (area under curve, 0.77; sensitivity, 0.69; specificity, 0.72), respectively (P value < .01). For the moderate-to-severely ischemic peri-infarct zone, mean parenchymal blood volume values of the involved hemisphere VOIs were lower compared with the uninvolved hemisphere VOIs (P value < .01). However, for the mild-to-moderately ischemic peri-infarct zone, there was no statistically significant difference between the mean parenchymal blood volume values of the involved and uninvolved hemisphere VOIs (P value > .05). CONCLUSIONS C-arm flat detector CT parenchymal blood volume maps in conjunction with optimal thresholds are sensitive and specific for the estimation of irreversibly infarcted parenchyma. Parenchymal blood volume maps allow reliable detection of moderate-to-severe ischemia; however, the potential for underestimation of mild-to-moderate ischemia exists.
منابع مشابه
Applicability of tableside flat panel detector CT parenchymal cerebral blood volume measurement in neurovascular interventions: preliminary clinical experience.
BACKGROUND AND PURPOSE CBV is a vital perfusion parameter in estimating the viability of brain parenchyma (eg, in cases of ischemic stroke or after interventional vessel occlusion). Recent technologic advances allow parenchymal CBV imaging tableside in the angiography suite just before, during, or after an interventional procedure. The aim of this work was to analyze our preliminary clinical ex...
متن کاملFeasibility of cerebral blood volume mapping by flat panel detector CT in the angiography suite: first experience in patients with acute middle cerebral artery occlusions.
BACKGROUND AND PURPOSE A new FPCT application offers the possibility of perfusion (FPCT CBV) and parenchymal (FPCT) imaging within the angiography suite. We tested the hypothesis that findings in FPCT CBV and FPCT would correlate with those obtained using MSCT and PCT. MATERIALS AND METHODS In 16 patients with acute MCA occlusion, FPCT CBV was performed immediately posttreatment. The volume o...
متن کاملIntegrated flat detector CT and live fluoroscopic-guided external ventricular drain placement within the neuroangiography suite
PURPOSE To demonstrate the feasibility of the application of integrated flat detector (FD) CT and fluoroscopic guidance (iGuide) for the placement of external ventricular drains (EVD) within the neuroangiography suite. METHODS A retrospective review of a prospectively maintained endovascular database identified six patients who underwent EVD placement using iGuide. Patient characteristics, op...
متن کاملResponse to letter to the editor. "CT angiography source-images and CT perfusion: are they complementary tools for ischemic stroke evaluation?".
Cerebral blood volume (CBV) can be measured using a C-arm flat detector angiographic system. The present report describes a case in which cerebral hyperperfusion was detected with the Neuro parenchymal blood volume (PBV) system (syngo Neuro PBV IR, Siemens Medical Solutions, Erlangen, Germany) during carotid artery stenting (CAS). An 89-year-old man was referred to our hospital for cerebral bra...
متن کاملA prospective, multicenter pilot study investigating the utility of flat detector derived parenchymal blood volume maps to estimate cerebral blood volume in stroke patients
PURPOSE Newer flat panel angiographic detector (FD) systems have the capability to generate parenchymal blood volume (PBV) maps. The ability to generate these maps in the angiographic suite has the potential to markedly expedite the triage and treatment of patients with acute ischemic stroke. The present study compares FP-PBV maps with cerebral blood volume (CBV) maps derived using standard dyn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 36 9 شماره
صفحات -
تاریخ انتشار 2015