External cross-validation of bioelectrical impedance analysis for the assessment of body composition in Korean adults

نویسندگان

  • Hyeoijin Kim
  • Chul-Hyun Kim
  • Dong-Won Kim
  • Mira Park
  • Hye Soon Park
  • Sun-Seek Min
  • Seung-Ho Han
  • Jae-Yong Yee
  • Sochung Chung
  • Chan Kim
چکیده

Bioelectrical impedance analysis (BIA) models must be validated against a reference method in a representative population sample before they can be accepted as accurate and applicable. The purpose of this study was to compare the eight-electrode BIA method with DEXA as a reference method in the assessment of body composition in Korean adults and to investigate the predictive accuracy and applicability of the eight-electrode BIA model. A total of 174 apparently healthy adults participated. The study was designed as a cross-sectional study. FM, %fat, and FFM were estimated by an eight-electrode BIA model and were measured by DEXA. Correlations between BIA_%fat and DEXA_%fat were 0.956 for men and 0.960 for women with a total error of 2.1%fat in men and 2.3%fat in women. The mean difference between BIA_%fat and DEXA_%fat was small but significant (P < 0.05), which resulted in an overestimation of 1.2 ± 2.2%fat (95% CI: -3.2-6.2%fat) in men and an underestimation of -2.0 ± 2.4%fat (95% CI: -2.3-7.1%fat) in women. In the Bland-Altman analysis, the %fat of 86.3% of men was accurately estimated and the %fat of 66.0% of women was accurately estimated to within 3.5%fat. The BIA had good agreement for prediction of %fat in Korean adults. However, the eight-electrode BIA had small, but systemic, errors of %fat in the predictive accuracy for individual estimation. The total errors led to an overestimation of %fat in lean men and an underestimation of %fat in obese women.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Total Fat, Percentage of Fat, Trunk Fat, Soft Lean and Mass Waist-Hip Ratio between Diabetic type II and Matched Non-Diabetic Iranians using Bioelectrical Impedance Analysis

Introduction: Research shows a relationship between diabetes (type II) and obesity. Bioelectrical Impedance Analysis (BIA) is a relatively new and approved method for the measurement of body composition. The aim of this study was to compare diabetic and non-diabetic adults on the basis of waist-hip ratio, total fat, percentage of fat, trunk fat, and soft lean mass. Methods: In this cross-sec...

متن کامل

Comparison of Muscle Mass, Total Body Water and Total Body Protein in Type II Diabetics with Healthy Matched Adults by Bioelectrical Impedance Analysis

Background: Bioelectrical impedance analysis (BIA) is a new and rapid technique to validate body composition. Several studies have used this technique to evaluate body compositions, such as muscle mass, in diabetic patients, but the results are very different. This may due the differences between diabetic patients and control group. Therefore, this study aimed to compare the muscle mass of diab...

متن کامل

Bioelectrical Impedance versus Body Mass Index for Predicting Body Composition Parameters in Sedentary Job Women

Objective: Nowadays the value of bioelectrical impedance analysis (BIA) in the estimation of body adiposity both on a clinical basis in the individual and epidemiologically in large populations is of great interest. The current study determine accuracy of BIA compared with body mass index (BMI) measurement for estimating body composition in a group of normal weight employee women with a sedenta...

متن کامل

Phase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis

Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...

متن کامل

A prediction equation for total body water from bioelectrical impedance in Japanese children.

Total body water (TBW) measured by isotope dilution techniques can be used to assess body composition safely and accurately in children. Unfortunately, this method is not readily available for most research projects, particularly when working with large groups of people, because the equipment is complicated and highly specialized. Bioelectrical impedance (BI) method is a simple, quick, and inex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -