Clinical monitoring of cardiac output assessed by transoesophageal echocardiography in anaesthetised dogs: a comparison with the thermodilution technique

نویسندگان

  • Matheus M. Mantovani
  • Denise T. Fantoni
  • André M. Gimenes
  • Jacqueline R. de Castro
  • Patrícia B. Flor
  • Keila K. Ida
  • Denise S. Schwartz
چکیده

BACKGROUND Cardiac output (CO) is an important haemodynamic parameter to monitor in patients during surgery. However, the majority of the techniques for measuring CO have a limited application in veterinary practice due to their invasive approach and associated complexity and risks. Transoesophageal echocardiography (TEE) is a technique used to monitor cardiac function in human patients during surgical procedures and allows CO to be measured non-invasively. This prospective clinical study aimed to compare the transoesophageal echocardiography using a transgastric view of the left ventricular outflow tract (LVOT) and the thermodilution (TD) technique for the assessment of CO during mean arterial pressure of 65-80 mmHg (normotension) and <65 mmHg (hypotension) in dogs undergoing elective surgery. Eight dogs were pre-medicated with acepromazine (0.05 mg/kg, IM), tramadol (4 mg/kg, IM) and atropine (0.03 mg/kg, IM), followed by anaesthetic induction with propofol (3-5 mg/kg IV) and maintenance with isoflurane associated with a continuous infusion rate of fentanyl (bolus of 3 μg/kg followed by 0.3 μg/kg/min). The CO was measured by TEE (COTEE) and TD (COTD) at the end of expiration during normotension and hypotension (induced by isoflurane). RESULTS There was a strong positive correlation between COTEE and COTD ​​(r = 0.925; P < 0.0001). The bias between COTD and COTEE was 0.14 ± 0.29 L/min (limits of agreement, -0.44 to 0.72 L/min). The percentage error of CO measured by the two methods was 12.32%. In addition, a strong positive correlation was found between COTEE and COTD during normotension (r = 0.995; P < 0.0001) and hypotension (r = 0.78; P = 0.0223). CONCLUSIONS The results of this study indicated that the transgastric view of the LVOT by TEE was a minimally invasive alternative to clinically monitoring CO in dogs during anaesthesia. However, during hypotension, the CO obtained by TEE was less reliable, although still acceptable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.

BACKGROUND AND OBJECTIVE During off-pump coronary bypass grafting, surgical manipulation and dislocation of the heart may cause cardiovascular instability. Monitoring of cardiac output facilitates intraoperative haemodynamic management but pulmonary artery catheters are often considered too invasive. Pulse contour analysis and transoesophageal echocardiography could serve as alternatives, but t...

متن کامل

Transoesophageal Doppler echocardiographic measurement of cardiac output by the mitral annulus method.

OBJECTIVE To compare cardiac output measured by the transoesophageal Doppler and thermodilution techniques. DESIGN Prospective direct comparison of paired measurements by both techniques in each patient. SETTING Intensive care unit in a cardiovascular centre. PATIENTS 65 patients after open heart surgery (mean (SD) age 53 (12) years). INTERVENTIONS Cardiac output was measured simultaneo...

متن کامل

Transoesophageal pulsed wave Doppler measurement of cardiac output during major vascular surgery: comparison with the thermodilution technique.

We measured cardiac output in 12 patients undergoing elective abdominal vascular surgery at specific times during the procedure with simultaneous thermodilution and transoesophageal pulsed Doppler echocardiographic techniques. No patient had clinical evidence of valvular heart disease before surgery. Five patients had echocardiographic evidence of mitral regurgitation on colour-coded Doppler. U...

متن کامل

Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography.

BACKGROUND End-diastolic volume indices determined by transpulmonary thermodilution and pulmonary artery thermodilution may give a better estimate of left ventricular preload than pulmonary capillary wedge pressure monitoring. The aim of this study was to compare volume preload monitoring using the two different thermodilution techniques with left ventricular preload assessment by transoesophag...

متن کامل

Follow up the Treatment Process of Mitral Valve Diseases by Radiography and Echocardiography in Dogs

Background: Mitral valve disease is the most common acquired heart disease in dogs. Mitral valve regurgitation (MR) due to endocardiosis is an important cause of morbidity and mortality in dog. Echocardiography as a non-invasive tool is routinely used to evaluate and diagnose different disorders in the heart. Objectives: The purpose of this study is to determine the efficacy of medical treatmen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2017