Improved spectral analysis for the motional Stark effect diagnostic.
نویسندگان
چکیده
The magnetic pitch angle and the magnitude from reversed field pinch plasmas in the Madison symmetric torus (MST) have been routinely obtained from fully resolved motional Stark effect (MSE) spectrum analyses. Recently, the spectrum fit procedure has been improved by initializing and constraining the fit parameters based on the MSE model in the atomic data and analysis structure. A collisional-radiative model with level populations nlm-resolved up to n = 4 and a simple Born approximation for ion-impact cross sections is used for this analysis. Measurement uncertainty is quantified by making MSE measurements with multiple views of a single spatial location, ranging 5%-15% for typical MST operation conditions. A multi-view fit improves the goodness of fit of MSE spectral features and background.
منابع مشابه
Note: Multi-point measurement of |B| in the gas-dynamic trap with a spectral motional Stark effect diagnostic.
An upgraded spectral motional Stark effect diagnostic has been installed on the gas-dynamic trap (GDT) experiment to enable spatially resolved measurement of |B|. A new low-noise charge-coupled device detector, combined with enhancements of the diagnostic neutral beam, allows single-shot profile measurements. Previously only single-point motional Stark effect measurements were possible, and det...
متن کاملMeasurements of the radial profile of magnetic field in the Gas-Dynamic Trap using a motional Stark effect diagnostic
We have implemented a spectral motional Stark effect diagnostic for spatially localized measurements of magnetic field on the Gas-Dynamic Trap ~GDT! magnetic mirror device. A 7 A, 40 keV diagnostic neutral hydrogen beam was focused to a current density of 0.25 A/cm in the measurement volume, allowing achievement of a radial resolution of 4.5 cm by viewing the beam at 45° with a well-defined lig...
متن کاملTwo-point motional Stark effect diagnostic for Madison Symmetric Torus.
A high-precision spectral motional Stark effect (MSE) diagnostic provides internal magnetic field measurements for Madison Symmetric Torus (MST) plasmas. Currently, MST uses two spatial views--on the magnetic axis and on the midminor (off-axis) radius, the latter added recently. A new analysis scheme has been developed to infer both the pitch angle and the magnitude of the magnetic field from M...
متن کاملRobotic calibration of the motional Stark effect diagnostic on Alcator C-Mod.
The capability to calibrate diagnostics, such as the Motional Stark Effect (MSE) diagnostic, without using plasma or beam-into-gas discharges will become increasingly important on next step fusion facilities due to machine availability and operational constraints. A robotic calibration system consisting of a motorized three-axis positioning system and a polarization light source capable of gene...
متن کاملSnapshot-imaging motional Stark effect polarimetry
Measurement of the motional Stark effect (MSE) for Balmer alpha light emitted from heating or diagnostic neutral beams is a standard technique for estimating plasma toroidal current density in tokamaks. Most techniques typically rely on a determination of the polarization angle or relative intensities of the multiplet components which are spectrally resolved using either an array of interferenc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 83 10 شماره
صفحات -
تاریخ انتشار 2012