Monitoring the penetration process of single microneedles with varying tip diameters.
نویسندگان
چکیده
Microneedles represent promising tools for delivery of drugs to the skin. However, before these microneedles can be used in clinical practice, it is essential to understand the process of skin penetration by these microneedles. The present study was designed to monitor both penetration depth and force of single solid microneedles with various tip diameters ranging from 5 to 37µm to provide insight into the penetration process into the skin of these sharp microneedles. To determine the microneedle penetration depth, single microneedles were inserted in human ex vivo skin while monitoring the surface of the skin. Simultaneously, the force on the microneedles was measured. The average penetration depth at 1.5mm displacement was similar for all tip diameters. However, the process of penetration depth was significantly different for the various microneedles. Microneedles with a tip diameter of 5µm were smoothly inserted into the skin, while the penetration depth of microneedles with a larger tip diameter suddenly increased after initial superficial penetration. In addition, the force at insertion (defined as the force at a sudden decrease in measured force) linearly increased with tip diameter ranging from 20 to 167mN. The force drop at insertion was associated with a measured penetration depth of approximately 160μm for all tip diameters, suggesting that the drop in force was due to the penetration of a deeper skin layer. This study showed that sharp microneedles are essential to insert microneedles in a well-controlled way to a desired depth.
منابع مشابه
Fiberoptic Microneedles for Transdermal Light Delivery
Shallow light penetration in tissue has been a technical barrier to the development of photothermal therapies for cancers in the epithelial tissues and skin. This problem can potentially be solved by utilizing minimally invasive probes to deliver light directly to target areas potentially >2 mm deep within tissue. To develop this solution, fiber optic microneedles capable of delivering light fo...
متن کاملFabrication of conical microneedles array using photolithography
Background and Aim: Microneedle technology has led to huge changes in the field of drug delivery medicine. Using microneedles, the drug can be injected locally, painlessly, and in very low and controlled doses with high precision. Local drug delivery through the skin with microneedles has many advantages over other methods of drug delivery. In this method, the drug does not enter the gastrointe...
متن کاملEffect of microneedle design on pain in human volunteers.
OBJECTIVES To design microneedles that minimize pain, this study tested the hypothesis that microneedles cause significantly less pain than a 26-gauge hypodermic needle, and that decreasing microneedle length and the number of microneedles reduces pain in normal human volunteers. METHODS Single microneedles with lengths ranging from 480 to 1450 microm, widths from 160 to 465 microm, thickness...
متن کاملPravastatin transdermal patch: Effect of the formulation and length of microneedles on in- vitro percutaneous absorption studies.
Transdermal patches loaded with pravastatin was previously characterized in another published study by Serrano-Castañeda et al; 2015. These transdermal patches (TP) were generated by the plate casting technique, the in vitro percutaneous absorption studies of TP were evaluated for three different formulations of TP with different quantities of Pluronic F-127 (PF-127): i) without PF-127 (TP W), ...
متن کاملPravastatin transdermal patch: Effect of the formulation and length of microneedles on in- vitro percutaneous absorption studies.
Transdermal patches loaded with pravastatin was previously characterized in another published study by Serrano-Castañeda et al; 2015. These transdermal patches (TP) were generated by the plate casting technique, the in vitro percutaneous absorption studies of TP were evaluated for three different formulations of TP with different quantities of Pluronic F-127 (PF-127): i) without PF-127 (TP W), ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the mechanical behavior of biomedical materials
دوره 40 شماره
صفحات -
تاریخ انتشار 2014