Prospective observational study for perioperative volume replacement with 6% HES 130/0,42, 4% gelatin and 6% HES 200/0,5 in cardiac surgery
نویسندگان
چکیده
BACKGROUND the constantly growing amount of different kinds of colloid fluids necessitates comparative investigations with regards to the safety and effectivity in clinical use of these preparations. Hence we compared three colloid fluids in an observational study. The objective was the exploration of the influence of these three colloids on blood coagulation, hemodynamics and renal function of the cardiac surgical patient. METHODS we included 90 patients undergoing an elective open-heart surgery with the use of the heart-lung machine and observed them consecutively. Group 1 [gelatin 4% (n = 30)], Group 2 [HES 200/0,5 (n = 30)] and Group 3 [HES 130/0,42 (n = 30)]. We measured the perioperative volume replacement, the administration of blood- and coagulation-products, the application of catecholamines, the renal function, blood gas and the platelet aggregation using multiplate electrode analyzer (Multiplate, Dynabyte medical, Munich, Germany). RESULTS the gelatin-group needed significantly more norepinephrine than the HES 130/0.42 group. The responsible surgeon considered the blood coagulation in the HES 200/0.5 group most frequently as impaired. Furthermore we saw a significant decrease in platelet function in the HES 200/0.5 group when performing the multiplate-analysis (ADP-and COL-test). HES 130/0.4 as well as gelatin 4% showed no significant change in platelet function. The gelatin-group and the HES 200/0.5 needed significantly more aprotinine than the HES 130/0.4 group. We saw no significant difference with regards to administration of blood and coagulation products between the three groups. The urinary excretion during the intervention was significantly higher in the HES 200/0.5 group and in the gelatin group than in the HES 130/0.4 group. CONCLUSIONS our results confirm the lower stabilizing effect of gelatin on circulation during fluid resuscitation. The blood coagulation was mostly impaired due to HES 200/0.5 confirmed by the multiplate®-analysis as well as by different clinical findings.
منابع مشابه
Large-dose hydroxyethyl starch 130/0.4 does not increase blood loss and transfusion requirements in coronary artery bypass surgery compared with hydroxyethyl starch 200/0.5 at recommended doses.
BACKGROUND Hydroxyethyl starch (HES) 130/0.4 may impair blood coagulation less than other HES solutions and, thus, may be used at larger doses without increasing the risk of postoperative bleeding. This study tested the hypothesis that volume replacement with 6% HES 130/0.4 at a dose of up to 50 ml/kg does not increase blood loss and transfusion requirements in elective coronary artery bypass s...
متن کاملHydroxyethylstarch and gelatin solutions impair blood coagulation after cardiac surgery: a prospective randomized trial.
BACKGROUND Colloids are often used after cardiac surgery as intravascular volume replacement therapy. Cardiac surgical patients have an increased risk of bleeding. Both hydroxyethylstarch (HES) and gelatin solutions impair haemostasis. We examined the impact and dose effect on coagulation of HES 130/0.4, gelatin, or Ringer's acetate solutions after cardiac surgery. METHODS Forty-five patients...
متن کاملComparison of the effects of gelatin and a modern hydroxyethyl starch solution on renal function and inflammatory response in elderly cardiac surgery patients.
BACKGROUND The effects of hydroxyethylstarch (HES) 130/0.4 6% and gelatin 4% on inflammation, endothelial integrity, and renal function after cardiac surgery were compared. METHODS Sixty patients aged >80 yr undergoing cardiac surgery were randomized to receive gelatin (n=30) or HES 130/0.4 (n=30). The colloid was used in the priming of the cardiopulmonary bypass circuit (500 ml) and for volu...
متن کاملThe use of meta-analyses for benefit/risk re-evaluations of hydroxyethyl starch
Whether hydroxyethyl starch (HES) is safe for perioperative use is not known. Evaluating HES in cardiac surgery, Jacob and colleagues suggested conclusion was of a more favorable safety profile for HES 130/0.4 [1]. The authors, however, wrongly stated that they followed the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines because the meta-analysis lacked a ...
متن کاملHydroxyethyl starch 130/0.42/6:1 for perioperative plasma volume replacement in 1130 children: results of an European prospective multicenter observational postauthorization safety study (PASS).
INTRODUCTION Third-generation hydroxyethyl starch (HES) is now approved also for the use in children, but safety studies including large numbers of pediatric patients are still missing. Therefore, we performed an European multicentric prospective observational postauthorization safety study (PASS) to evaluate the use of HES 130/0.42/6:1 in normal saline (ns-HES) or a balanced electrolyte soluti...
متن کامل