Contact heat thermal threshold testing in beagle dogs: baseline reproducibility and the effect of acepromazine, levomethadone and fenpipramide

نویسندگان

  • Marina Verena Hoffmann
  • Sabine Beate Rita Kästner
  • Manfred Kietzmann
  • Sabine Kramer
چکیده

BACKGROUND In this methodology article a thermal threshold testing device designed to test nociception in cats was assessed in six dogs. The purpose of this study was to investigate baseline reproducibility of thermal thresholds obtained by the contact heat testing device, to assess the influence of acepromazine and levomethadone and fenpipramide in dogs. The relationship between change in nociceptive thermal threshold and the opioid's plasma concentration was determined. Six adult beagle dogs received levomethadone (0.2 mg/kg), acepromazine (0.02 mg/kg) or saline placebo by intramuscular injection (IM) in a randomized cross-over design. Three baseline nociceptive thermal threshold readings were taken at 15 minutes intervals prior to treatment. Further readings were made at 15, 30, 45, 60, 90, 120, 150, 180, 210, 240, 270, 300, 330, 360, 420 and 480 minutes after injection. A sedation score was assigned at every reading. Four saline placebo treatments were performed to assess baseline reproducibility. Levomethadone serum concentrations were measured prior and 0.5, 1, 2, 4, 8, 12 and 24 hours after drug dosing in a separate occasion. RESULTS Acepromazine did not seem to increase the thermal threshold at any time. After levomethadone there was a significant rise of the thermal threshold between 15 to 120 minutes at serum concentrations between 22.6-46.3 ng/mL. Baseline reproducibility was stable in adult beagle dogs. CONCLUSION The thermal threshold testing system is a suitable device for nociceptive threshold testing in dogs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Acepromazine on Electroencephalographic Activity in Normal Sedated Dogs

Objective: To determine the effect of intravenous acepromazine on the electroencephalogram (EEG) of normal Beagle dogs. Sample Population: Twelve healthy beagle dogs Procedures: Dogs were sedated and the EEG recorded for 20 minutes. Acepromazine was then injected intravenously in either low or high dose with the order chosen randomly and EEG recording continued for 30 minutes. Each dog received...

متن کامل

Nociceptive thermal threshold testing in horses – effect of neuroleptic sedation and neuroleptanalgesia at different stimulation sites

BACKGROUND Aim of the study was to compare the effect of neuroleptic sedation with acepromazine and neuroleptanalgesia with acepromazine and buprenorphine on thermal thresholds (TT) obtained at the nostrils and at the withers. The study was carried out as a randomized, blinded, controlled trial with cross-over design. Thermal thresholds were determined by incremental contact heat applied to the...

متن کامل

Effect of Contact Pressure and Frequency on Contact Heat Transfer Between Exhaust Valve and its Seat

The hot gases produced by the internal combustion engines passes through the exhaust valve and causes high temperatures in the exhaust valve and its seat. To avoid damaging the exhaust valve, heat must be transferred from the valve to its seat during the contact they make at the opening and closing cycle. Heat transfer rate from the exhaust valve to its seat is a function of many factors. One o...

متن کامل

Comparison of the effects of different doses of acepromazine-xylazine on the electrocardiogram in dogs

Seventy seven adult large mixed breed dogs of either sex were included in this study. The animals were randomly divided into four groups and received the following drug combinations intramuscularly: Group 1 xylazine (0.5 mg/kg) and acepromazine (0.05 mg/kg), Group 2 xylazine (0.8 mg/kg) and acepromazine (0.03 mg/kg), Group 3 xylazine (0.3 mg/kg) and acepromazine (0.08 mg/kg) and Group 4 xylazin...

متن کامل

Sensitivity Analysis of Different Parameters Affecting Thermal Contact Conductance

In internal combustion engines, exhaust valve and its seat gain considerable temperature as the hot gases exit through them. So, the rate of heat transfer should be under control. In this study, the contact heat transfer coefficient has been estimated. An experimental study on an Air-Cooled internal combustion engine cylinder head has been considered. Using the measured temperatures of sensors ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2012