Improved accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.

نویسندگان

  • John R Feiner
  • Philip E Bickler
چکیده

BACKGROUND Methemoglobin in the blood cannot be detected by conventional pulse oximetry and may bias the oximeter's estimate (Spo(2)) of the true arterial functional oxygen saturation (Sao(2)). A recently introduced "pulse CO-oximeter" (Masimo Rainbow SET® Radical-7) that measures SpMet, a noninvasive measurement of the percentage of methemoglobin in arterial blood (%MetHb), was shown to read spuriously high values during hypoxia. In this study we sought to determine whether the manufacturer's modifications have improved the device's ability to detect and accurately measure methemoglobin and deoxyhemoglobin simultaneously. METHODS Twelve healthy adult volunteer subjects were fitted with sensors on the middle finger of each hand, and a radial arterial catheter was placed for blood sampling. Intravenous administration of ∼300 mg of sodium nitrite elevated subjects' methemoglobin levels to a 7% to 11% target level, and hypoxia was induced to different levels of Sao(2) (70% to 100%) by varying fractional inspired oxygen. Pulse CO-oximeter readings were compared with arterial blood values measured with a Radiometer ABL800 FLEX multi-wavelength oximeter. Pulse CO-oximeter methemoglobin reading performance was analyzed by the bias (SpMet-%MetHb), and by observing the incidence of meaningful reading errors and predictive value at the various hypoxia levels. Spo(2) bias (Spo(2)--Sao(2)), precision, and root-mean-square error were evaluated during conditions of elevated methemoglobin. RESULTS Observations spanned 74% to 100% Sao(2) and 0.4% to 14.4% methemoglobin with 307 blood draws and 602 values from the 2 oximeters. Masimo methemoglobin reading bias and precision over the full Sao(2) span was 0.16% and 0.83%, respectively, and was similar across the span. Masimo Spo(2) readings were biased -1.93% across the 70% to 100% Sao(2) range. CONCLUSIONS The Rainbow's methemoglobin readings are acceptably accurate over an oxygen saturation range of 74%-100% and a methemoglobin range of 0%-14%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive measurements of carboxyhemoglobin and methemoglobin in children with sickle cell disease.

Assessment of oxyhemoglobin saturation in patients with sickle cell disease (SCD) is vital for prompt recognition of hypoxemia. The accuracy of pulse oximeter measurements of blood oxygenation in SCD patients is variable, partially due to carboxyhemoglobin (COHb) and methemoglobin (MetHb), which decrease the oxygen content of blood. This study evaluated the accuracy and reliability of a non-inv...

متن کامل

The measurement of dyshemoglobins and total hemoglobin by pulse oximetry.

PURPOSE OF REVIEW Recent advances in pulse oximetry have made it possible to noninvasively measure total hemoglobin, as well as the two most common dyshemoglobins. This review will trace the development and clinical application of multiwavelength pulse oximetry. RECENT FINDINGS Until now, commercially produced pulse oximeters have utilized two wavelengths of light and could measure only the r...

متن کامل

Pulse oximetry and cardiorespiratory changes during upper gastrointestinal endoscopy in dogs

Objective- The objective of the present study was to determine the changes in heart rate, respiratory rate and arterial Oxygen saturation (SpO2) by administration of three drug combinations during upper gastrointestinal endoscopy. Design- Experimental study. Animals- 21 healthy and adults dog were randomly divided into three groups. Procedures- The IV combination of 6.5 mg/kg ketamine and 0....

متن کامل

Benzocaine and lidocaine induced methemoglobinemia after bronchoscopy: a case report

INTRODUCTION Methemoglobinemia is a rare cause of hypoxemia, characterized by abnormal levels of oxidized hemoglobin that cannot bind to and transport oxygen. CASE PRESENTATION A 62-year-old male underwent bronchoscopy where lidocaine oral solution and Hurricaine spray (20% benzocaine) were used. He developed central cyanosis and his oxygen saturation was 85% via pulse oximetry. An arterial b...

متن کامل

Comparison of oxygen saturation by pulse oximetry and co-oximetry during exercise testing in patients with COPD.

INTRODUCTION Measurement of oxygen saturation by pulse oximetry (SpO2) is frequently performed during exercise testing of patients with COPD to monitor for hypoxemia. The purpose of this study was to assess the accuracy and precision of pulse oximetry during exercise. We hypothesized that the SpO2 would more closely reflect oxygen saturation as measured by co-oximetry (SaO2) when it was correct...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 111 5  شماره 

صفحات  -

تاریخ انتشار 2010