How large must an iridotomy be?
نویسنده
چکیده
Four cases of acute angle closure glaucoma in eyes with a small but patent Nd-YAG laser iridotomy are presented, and similar cases in the literature are reviewed. Theoretically a 15 microns diameter iridotomy should be large enough to prevent angle closure glaucoma due to pupil block. Mechanisms by which larger iridotomies fail to prevent angle closure glaucoma, and the role of provocation tests following iridotomy, are discussed. An iridotomy should be at least 150-200 microns in diameter if acute angle closure glaucoma is to be reliably prevented.
منابع مشابه
Effects of Argon Laser Iridotomy on the Corneal Endothelium of Pigmented Rabbit Eyes
PURPOSE In Asian countries, laser iridotomy for the treatment of angle-closure glaucoma is a common cause of bullous keratopathy, which may be associated with a shallow anterior chamber and dark iris pigmentation in Asians. Several cases of corneal decompensation after argon laser iridotomy have been reported. In the present study, we evaluated the harmful effects of argon laser iridotomy on th...
متن کاملPatency of small laser iridotomy evaluated using anterior-segment optical coherence tomography
We report the case of a patient with recurrent acute angle-closure glaucoma who had undergone a previous laser iridotomy. Because the initial iridotomy was small, patency could not be determined by slit-lamp examination. Therefore, anterior-segment optical coherence tomography was used to evaluate the patency. Cross-sectional images showed the presence of a membrane with an anterior bowing conf...
متن کاملA photometric study of the effect of pupil dilatation on Nd:YAG laser iridotomy area.
A photometric study of the effect of pupil dilatation on Nd:YAG laser iridotomy area was performed in 21 eyes of 21 patients. The iridotomy area was 0.075 (0.055) mm-2 (mean (SD)) before pupil dilatation and 0.073 (0.070) mm-2 after pupil dilatation (t test NS). Iridotomy area after pupil dilatation correlated with iridotomy area before pupil dilatation (r = 0.815, p < 0.01) but did not signifi...
متن کاملRecurrent Occlusion of Laser Iridotomy Sites After Posterior Chamber Phakic IOL Implantation
We report a case of recurrent occlusion of laser iridotomy (LI) sites after a Visian ICL (Implantable contact lens version 4, Staar Surgical AG, Nidau, Switzerland) implantation. A 45-year-old woman had bilateral ICL implantation after placement of two peripheral LI sites in each eye to prevent pupillary block. At one month after the operation, severe narrowing or occlusion of four LI sites occ...
متن کاملComparison of laser iridotomy using short duration 532-nm Nd: YAG laser (PASCAL) vs conventional laser in dark irides.
AIM To evaluate the outcome of laser iridotomy using 532-nm Nd: YAG laser (PASCAL) with short pulse duration and Nd: YAG laser compared to conventional combined laser iridotomy. METHODS Retrospective, nonrandomized, comparative case series. Forty-five eyes of 34 patients underwent laser iridotomy. Twenty-two eyes underwent iridotomy using short duration PASCAL and Nd: YAG laser, and 23 eyes u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 74 10 شماره
صفحات -
تاریخ انتشار 1990