Stability studies of common biochemical analytes in serum separator tubes with or without gel barrier subjected to various storage conditions
نویسندگان
چکیده
INTRODUCTION The collected and shipped blood samples are exposed to a various extra-analytical factors prior to analysis. The aim of the study was to determine the stability of analytes in serum gel tubes and plain tubes exposed to a range of storage temperatures and times after centrifugation. MATERIALS AND METHODS Fifteen healthy volunteers were recruited and venous blood was collected into four tubes, two with and two without gel separator. Analyzing the baseline samples in 30 min, all were stored at 4 degrees C or 24 degrees C for 6, 12, 18, 24, 30, 36, 48 and 72 hours and 1 week. Sixteen biochemical anaytes were measured on each sample. Variations remained under the desirable bias considered as clinically insignificant. RESULTS On day three, most analytes remained stable including albumin, protein, creatinine, cholesterol, triglycerides, gamma-glutamyl transferase (GGT), alkaline phosphatase (ALP), alanine aminotransferase (ALT), creatine kinase (CK), lactate dehydrogenase (LD) regardless of tube types. Glucose concentration decreased markedly (P = 0.001) beginning from the first hours of storage in plain serum. The stability maximized for the analytes including glucose, total bilirubin, urea nitrogen (BUN), uric acid stored at 4 degrees C in gel tubes. Aspartate aminotransferase (AST) activity increased significantly (P = 0.002) up to 48-h, however bias was not significant clinically. High density lipoprotein (HDL) concentration was stable in gel tubes at 24 degrees C, in plain tubes at 4 degrees C stored up to 36-h. CONCLUSION Serum gel or non-gel tubes might be used interchangeably for 11 analytes chilled or at 24 degrees C, whereas some restrictions must be applied for glucose, AST, BUN, HDL, and uric acid.
منابع مشابه
Stability of common biochemical analytes in serum gel tubes subjected to various storage temperatures and times pre-centrifugation.
BACKGROUND Blood samples collected in rural and remote areas of Australasia are often exposed to a range of environmental conditions prior to analysis in a laboratory. The aim of this study was to determine analyte stability of venous blood specimens in serum gel tubes exposed to a range of storage temperatures and times prior to centrifugation. METHODS Thirty healthy adult volunteers were en...
متن کاملComparisonof Plasticvs. Glass EvacuatedSerum-Separator(SSTTM)Blood-Drawing Tubes for CommonClinicalChemistryDeterminations
We evaluated a plastic evacuated blood-drawing tube containing an integral serum-separating barrier gel, by direct comparison with a glass counterpart. The plastic tube demonstrated no differences when compared for common clinical chemistry analytes with multiple types of instruments and systems. A total of 260 such different combinations were studied with emphasis on tests sensitive to drawing...
متن کاملThrombin-Accelerated Quick Clotting Serum Tubes: An Evaluation with 22 Common Biochemical Analytes
Clot activator serum tubes have significantly improved turnaround times for result reporting compared to plain tubes. With increasing workload and service performance expectations confronting clinical laboratories with high-volume testing and with particular emphasis on critical analytes, attention has focussed on preanalytical variables that can be improved. We carried out a field study on the...
متن کاملEffects of storage times and temperatures on T3, T4, LH, prolactin, insulin, cortisol and progesterone concentrations in blood samples from cows.
Little is known about stability of hormones in blood samples stored under various conditions. This study was conducted to examine stability of triiodothyronine (T3), thyroxine (T4), luteinizing hormone (LH), prolactin, insulin, cortisol and progesterone in blood and serum samples. Experiment 1 was designed to determine if concentrations of these hormones were affected by exposure to cellular el...
متن کاملCorrigendum to “Biomarkers for diagnosis of pediatric acute neuropsychiatric syndrome (PANS) – Sensitivity and specificity of the Cunningham panel” [J. Neuroimmunol. 312. (2017) 31–37]
We have been informed that Moleculera Labs recommend Red Top glass tubes when collecting blood for the Cunningham panel. In our study (Hesselmark and Bejerot, 2017) we have used serum sampling tubes (BD Vacutainer® SSTTM II Advance tubes, Gold Top) but erroneously reported sampling in “serum sampling tube (BD Vacutainer, yellow top)” (Section 2.6 in our paper). The use of another blood collecti...