Double-gated myocardial ASL perfusion imaging is robust to heart rate variation.
نویسندگان
چکیده
PURPOSE Cardiac motion is a dominant source of physiological noise (PN) in myocardial arterial spin labeled (ASL) perfusion imaging. This study investigates the sensitivity to heart rate variation (HRV) of double-gated myocardial ASL compared with the more widely used single-gated method. METHODS Double-gating and single-gating were performed on 10 healthy volunteers (n = 10, 3F/7M; age, 23-34 years) and eight heart transplant recipients (n = 8, 1F/7M; age, 26-76 years) at rest in the randomized order. Myocardial blood flow (MBF), PN, temporal signal-to-noise ratio (SNR), and HRV were measured. RESULTS HRV ranged from 0.2 to 7.8 bpm. Double-gating PN did not depend on HRV, while single-gating PN increased with HRV. Over all subjects, double-gating provided a significant reduction in global PN (from 0.20 ± 0.15 to 0.11 ± 0.03 mL/g/min; P = 0.01) and per-segment PN (from 0.33 ± 0.23 to 0.21 ± 0.12 mL/g/min; P < 0.001), with significant increases in global temporal SNR (from 11 ± 8 to 18 ± 8; P = 0.02) and per-segment temporal SNR (from 7 ± 4 to 11 ± 12; P < 0.001) without significant difference in measured MBF. CONCLUSION Single-gated myocardial ASL suffers from reduced temporal SNR, while double-gated myocardial ASL provides consistent temporal SNR independent of HRV. Magn Reson Med 77:1975-1980, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
منابع مشابه
High negative predictive value of workload ≥7 METS on exercise testing in patients with normal gated myocardial perfusion imaging: Was imaging really required?
Introduction: Good functional capacity has a high negative predictive value (NPV) in patients with known or suspected coronary artery disease (CAD) similar to a normal gated myocardial perfusion imaging (GMPI). Aim of this study was to evaluate NPV of functional capacity during treadmill exercise in patients with normal GMPI in Pakistani population. Methods: This was a prospective study which ...
متن کاملDetermination of normal ranges of regional and global phase parameters using gated myocardial perfusion imaging with Cedars-Sinai’s QGS software
Introduction: Myocardial perfusion imaging using gated SPECT and phase analysis is an effective tool in evaluation of mechanical dyssynchrony. The purpose of this study was to determine the normal ranges of global and regional phase parameters. Methods: A total of 100 patients with normal resting and stress electrocardiograms, low pretest likelihood for c...
متن کاملThe role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method
Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...
متن کاملArterial spin labeled MRI detects clinically relevant increases in myocardial blood flow with vasodilatation
OBJECTIVES This study sought to determine whether arterial spin labeled (ASL) cardiac magnetic resonance (CMR) is capable of detecting clinically relevant increases in regional myocardial blood flow (MBF) with vasodilator stress testing in human myocardium. BACKGROUND Measurements of regional myocardial perfusion at rest and during vasodilatation are used to determine perfusion reserve, which...
متن کاملDiagnostic Accuracy of Gated-SPECT Myocardial Perfusion Imaging and Exercise Stress Test for Diagnosis of Coronary Artery Disease
Background and Objective:Accurate diagnosis of CAD using noninvasive procedures is of great importance. The aim of the study is to assess diagnostic accuracy of myocardial perfusion imaging and compare it with exercise stress test in order to decipher a more accurate and cost-effective method for CAD detection. Materials and Methods:Of 430 consecutive patients suspected with CAD, 104 performed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 77 5 شماره
صفحات -
تاریخ انتشار 2017