Simulation Analysis of Solution Transportation Absorption Chiller with the Capacity from 25 RT to 1000 RT
نویسندگان
چکیده
Utilization of wasted heat instead of fuel combustion is effective to reduce primary energy consumption for mitigating global warming problem. Because wasted heat sources are not necessarily located close to areas of heat demand, one of the difficulties is that wasted heat has to be transferred from heat source side to heat demand side, which may require heat transportation over long distance. From this point we proposed and have examined new idea of heat transportation using ammonia-water as the working fluid which system is named Solution Transportation Absorption chiller, in short STA. Our previous studies of STA were mainly the experimental investigation with STA facility which cooling power was 25RT (90kW). As a result, the COP of STA was found almost same value 0.65 with the conventional absorption chiller without depending on the transportation distances. The simulation using AspenHYSYS also examined with same experimental condition. The experimental data showed good agreement with the simulation calculation. In this study, we examined the large-scale cooling power STA on simulation. The examination cooling powers were from 90 kW (25RT) to 3517 kW (1000RT). All cooling power achieved around COP 0.64 including pump power consumptions. In addition, we performed the dynamic simulation. As the results, there was no effect of pipeline size on the cooling capacities and mass flow rates. Furthermore, the stability time of the cooling capacities and mass flow rates were almost same regardless of the pipeline size and cooling capacity. In other words, STA may be achieved the same COP even though having various complex conditions compared with the conventional absorption chiller.
منابع مشابه
Transient Characteristics of a Single-Effect Absorption Refrigeration Cycle
This paper deals with a lumped-parameter dynamic simulation of a single-effect LiBr-H2O absorption chiller. In many studies the thermodynamic properties of LiBr-H2O solution were taken from some approximate relations causing the results to be somewhat inaccurate. These relations were used to solve simultaneous differential equations involving the continuity of species constituting the LiBr-H2O ...
متن کاملOptimal Short-Term Scheduling of Multi-Chiller Plants Considering Energy Requirement of Cooling Towers, Pumps and Chillers
During extremely hot summer days, air conditioning systems are known as major electricity consumers in residential, commercial and industrial sectors. Moreover, high energy requirement of multiple-chiller plants may cause an interconnected power grid be faced with annual on-peak electrical demand, load-generation mismatch, voltage collapse and catastrophic wide area blackout. Therefore, this pa...
متن کاملThermo-economic analysis of absorption chiller integrated with a GE-F5 gas turbine for power enhancement (Zanbagh power plant, studied case)
The efficiency and output power of gas turbine power plants are heavily affected by ambient air temperature. To compensate this defect, some cooling technologies and technics are applied. In this paper, the effect of applying an absorption chiller by recovering waste heat from gas turbine flue gas has been investigated. For this purpose, the behavior of a GE-F5 gas turbine was modeled by coding...
متن کاملThermoeconomic analysis of a hybrid PVT solar system integrated with double effect absorption chiller for cooling/hydrogen production
A novel solar-based combined system which is consisting of a concentrated PV, a double effect LiBr-H2O absorption chiller, and a Proton Exchange Membrane (PEM) is proposed for hydrogen production. A portion of the received energy is recovered to run a double effect absorption chiller and the rest is turned into electricity, being consumed in the PEM electrolyzer for hydrogen producti...
متن کاملDetection of avian reoviruses causing tenosynovitis in breeder flocks in Iran by reverse transcription-polymerase chain reaction (RT-PCR) and restriction enzyme fragment length polymorphism (RFLP)
BACKGROUND:Avian reoviruses (ARVs) are members of theOrthoreovirus genus; one of the 12 genera of the Reoviridaefamily. The ARVs are the cause of some important diseases inpoultry such as reovirus-induced arthritis, tenosynovitis,chronic respiratory disease, and mal-absorption syndrome.OBJECTIVES: In this study, the presence of ARVs in the Iranianbreeder flocks was investigated through reverse ...