Regularized image reconstruction with an anatomically adaptive prior for PET
نویسندگان
چکیده
The incorporation of accurately aligned anatomical information as a prior to guide reconstruction and noise regularization in positron emission tomography (PET) has been suggested in many previous studies. However, the advantages of this approach can only be realized if the exact lesion outline is also available. In practice, the anatomical imaging modality may be unable to differentiate between normal and pathological tissues, and thus the edges of lesions seen in the anatomical image may not correspond to functional boundaries in the emission image. In this study, we explored an alternative approach to incorporating an anatomical prior into PET image reconstruction. Of particular interest was the realistic situation where lesions are apparent in the emission images but not in the corresponding anatomical images. In the proposed method, regional information obtained from the anatomical prior was used to estimate an anatomically adaptive anisotropic median-diffusion filtering (AAMDF) prior. This smoothing prior was determined and applied adaptively to each anatomical region on the emission image and then assembled to form a prior image for the next iteration in the reconstruction process. We formulated a two-step joint estimation reconstruction scheme to update the estimated image and prior image iteratively. The proposed AAMDF prior was evaluated and compared with maximum a posteriori (MAP) reconstruction methods with and without anatomical side information. In experiments using synthetic and physical phantom data, the AAMDF prior yielded overall higher lesion-tobackground contrast and less error in lesion estimation than other algorithms 0031-9155/09/247379+22$30.00 © 2009 Institute of Physics and Engineering in Medicine Printed in the UK 7379
منابع مشابه
Adaptive Image Dehazing via Improving Dark Channel Prior
The dark channel prior (DCP) technique is an effective method to enhance hazy images. Dark channel is an image with the same size as the hazy image which represents the haze severity in different places of the image. The DCP method suffers from two problems: it is incapable for removing haze from smooth regions, causing blocking effects on these areas; it cannot properly reduce a haze with a no...
متن کاملBlock-Based Compressive Sensing Using Soft Thresholding of Adaptive Transform Coefficients
Compressive sampling (CS) is a new technique for simultaneous sampling and compression of signals in which the sampling rate can be very small under certain conditions. Due to the limited number of samples, image reconstruction based on CS samples is a challenging task. Most of the existing CS image reconstruction methods have a high computational complexity as they are applied on the entire im...
متن کاملEffect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET
Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...
متن کاملAssessment of the Wavelet Transform for Noise Reduction in Simulated PET Images
Introduction: An efficient method of tomographic imaging in nuclear medicine is positron emission tomography (PET). Compared to SPECT, PET has the advantages of higher levels of sensitivity, spatial resolution and more accurate quantification. However, high noise levels in the image limit its diagnostic utility. Noise removal in nuclear medicine is traditionally based on Fourier decomposition o...
متن کاملEdge Artifacts in Point Spread Function-based PET Reconstruction in Relation to Object Size and Reconstruction Parameters
Objective(s): We evaluated edge artifacts in relation to phantom diameter and reconstruction parameters in point spread function (PSF)-based positron emission tomography (PET) image reconstruction.Methods: PET data were acquired from an original cone-shaped phantom filled with 18F solution (21.9 kBq/mL) for 10 min using a Biograph mCT scanner. The images were reconstructed using the baseline or...
متن کامل