The cytocam video microscope. a new method for visualising the microcirculation using incident dark field (IDF) technology
نویسندگان
چکیده
UNLABELLED We report a new microcirculatory assessment device, the Braedius Cytocam, an Incident Dark Field (IDF) video microscope, and compare it with a precursor device utilising side stream dark field (SDF) imaging. METHODS Time matched measurements were made with both devices from the sublingual microcirculation of pigs subjected to traumatic injury and hemorrhagic shock at baseline and during a shock phase. Images were analysed for vessel density, microcirculatory flow and image quality. RESULTS There were no differences in density or flow data recorded from the two devices at baseline [TVD IDF 14.2 ± 2.4/TVD SDF 13.2 ± 2.0, p 0.17] [MFI IDF 3 (2.8-3.0)/MFI SDF 3 (2.9-3.0), p 0.36] or during the shock state [TVD IDF 11.64 ± 3.3/TVD SDF 11.4 ± 4.0 p = 0.98] [MFI IDF 1.9 (0.6-2.7)/MFI SDF 1.7 (0.3-2.6) p 0.55]. Bland and Altman analysis showed no evidence of significant bias. Vessel contrast was significantly better with the IDF device for both capillaries [17.1 ± 3.9 (IDF) v 3.4 ± 3.6 (SDF), p = 0.0006] and venules [36.1 ± 11.4 (IDF) v 26.4 ± 7.1 (SDF) p 0.014] CONCLUSION The Braedius Cytocam showed comparable vessel detection to a precursor device during both baseline and low flow (shock) states.
منابع مشابه
Cytocam-IDF (incident dark field illumination) imaging for bedside monitoring of the microcirculation
BACKGROUND Orthogonal polarized spectral (OPS) and sidestream dark field (SDF) imaging video microscope devices were introduced for observation of the microcirculation but, due to technical limitations, have remained as research tools. Recently, a novel handheld microscope based on incident dark field illumination (IDF) has been introduced for clinical use. The Cytocam-IDF imaging device consis...
متن کاملA comparison of the quality of image acquisition between the incident dark field and sidestream dark field video-microscopes
BACKGROUND The 'Cytocam' is a third generation video-microscope, which enables real time visualisation of the in vivo microcirculation. Based upon the principle of incident dark field (IDF) illumination, this hand held computer-controlled device was designed to address the technical limitations of its predecessors, orthogonal polarization spectroscopy and sidestream dark field (SDF) imaging. In...
متن کاملChanges in labial capillary density on ascent to and descent from high altitude
Present knowledge of how the microcirculation is altered by prolonged exposure to hypoxia at high altitude is incomplete and modification of existing analytical techniques may improve our knowledge considerably. We set out to use a novel simplified method of measuring in vivo capillary density during an expedition to high altitude using a CytoCam incident dark field imaging video-microscope. Th...
متن کاملMicrocirculatory assessment of patients under VA-ECMO
BACKGROUND Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is an effective technique for providing emergency mechanical circulatory support for patients with cardiogenic shock. VA-ECMO enables a rapid restoration of global systemic organ perfusion, but it has not been found to always show a parallel improvement in the microcirculation. We hypothesized in this study that the response...
متن کاملFunctional evaluation of sublingual microcirculation indicates successful weaning from VA-ECMO in cardiogenic shock
BACKGROUND Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is increasingly adopted for the treatment of cardiogenic shock (CS). However, a marker of successful weaning remains largely unknown. Our hypothesis was that successful weaning is associated with sustained microcirculatory function during ECMO flow reduction. Therefore, we sought to test the usefulness of microcirculatory im...