Accuracy and repeatability of joint angles measured using a single camera markerless motion capture system.
نویسندگان
چکیده
Markerless motion capture systems have developed in an effort to evaluate human movement in a natural setting. However, the accuracy and reliability of these systems remain understudied. Therefore, the goals of this study were to quantify the accuracy and repeatability of joint angles using a single camera markerless motion capture system and to compare the markerless system performance with that of a marker-based system. A jig was placed in multiple static postures with marker trajectories collected using a ten camera motion analysis system. Depth and color image data were simultaneously collected from a single Microsoft Kinect camera, which was subsequently used to calculate virtual marker trajectories. A digital inclinometer provided a measure of ground-truth for sagittal and frontal plane joint angles. Joint angles were calculated with marker data from both motion capture systems using successive body-fixed rotations. The sagittal and frontal plane joint angles calculated from the marker-based and markerless system agreed with inclinometer measurements by <0.5°. The systems agreed with each other by <0.5° for sagittal and frontal plane joint angles and <2° for transverse plane rotation. Both systems showed a coefficient of reliability <0.5° for all angles. These results illustrate the feasibility of a single camera markerless motion capture system to accurately measure lower extremity kinematics and provide a first step in using this technology to discern clinically relevant differences in the joint kinematics of patient populations.
منابع مشابه
Feasibility of a single camera markerless motion capture system to accurately measure flexion-extension
INTRODUCTION Traditional motion capture techniques use markers to measure movement. However, markers are prone to soft tissue artifact and experimental error [1] as well as possible impedance to natural motion. Another significant challenge is the ability to use optical motion capture systems in a variety of natural setting such as a patient’s home, on the sports field, or in public. This has l...
متن کاملComparison of lower limb and trunk kinematics between markerless and marker-based motion capture systems.
Three dimensional (3-D) motion capture systems are used by researchers and clinicians to analyze the kinematics of human movement. Traditional marker based systems are time consuming and limit the size of studies. Markerless 3-D systems are quicker to use but the differences between data captured in each system is unclear. AIM To examine the relationship of kinematic data captured by marker b...
متن کاملComparison of Markerless and Marker-Based Motion Capture Technologies through Simultaneous Data Collection during Gait: Proof of Concept
During the last decade markerless motion capture techniques have gained an increasing interest in the biomechanics community. In the clinical field, however, the application of markerless techniques is still debated. This is mainly due to a limited number of papers dedicated to the comparison with the state of the art of marker based motion capture, in term of repeatability of the three dimensi...
متن کاملEstimation of the Accuracy of a Shape-from-silhouette Markerless Motion Capture System
INTRODUCTION The most common methods for accurate capture of three-dimensional human motion require a laboratory environment and the attachment of markers or fixtures to the body segments. These laboratory conditions can cause adaptive changes to normal patterns of locomotion that introduce experimental artifact. For example, it has been shown that attaching straps to the thigh or shank alters ...
متن کاملWhat are the current limits of the KinectTM sensor?
The Kinect sensor offers new perspectives for the development and application of affordable, portable and easy-to-use markerless motion capture (MMC) technology. However, at the moment, accuracy of this device is still not known. In this study we compare results from Kinect (MMC) with those of a stereophotogrammetric system (marker based system [MBS]). 27 subjects performed a deep squatting mot...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 47 2 شماره
صفحات -
تاریخ انتشار 2014