Comparative Study of Two Virtual Flux DPC Methods applied to Shunt Active Filter
نویسندگان
چکیده
The dynamic and static performance of the Shunt Active Filter depends strongly on adopted control methods. This paper deals with Virtual Flux Based Direct Power Control Methods for Shunt Active. Two commonly used VF-DPC algorithms (Fuzzy-DPC and classical DPC) are presented and discussed with respect to the resulting switching frequency, the harmonics compensation, the spectrum of the current source and the implementation complexity. The proposed control strategies for the active filter have been tested in the Matlab/Simulink environment. The simulation comparison results show that the Fuzzy DPC is more efficient.
منابع مشابه
Active Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads
Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...
متن کاملPerformance Scrutiny of Two Control Schemes Based on DSM and HB in Active Power Filter
This paper presents a comparative analysis between two current control strategies, constant source power and generalized Fryze current, used in Active Power Filter (APF) applications having three different modulation methods. The Hysteresis Band (HB) and first-order Delta-Sigma Modulation (DSM) as well as the second-order DSM is applied. The power section of the active power filter is viewed as...
متن کاملMitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کاملA Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach
This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...
متن کامل