Measurement of Cesium-137 and Cobalt-60 Gamma Radiation With a Pressure Ionization Chamber

نویسنده

  • G. R. Grove
چکیده

The characteristics of the pressure ionization chamber at t he National Bureau of Standards have been studied for the gamma radiation from a cesium-137 sou rce (0.6614 Mev) and from a cobalt-60 source (1.1715 and 1.3316 Mev). The dosage rates produced in air by these sources were measured with this chamber with an accuracy of about 2 percent. Dosage rates obtained with an extrapolation chamber and a Victoreen thimble chamber agreed with the values measured by the pressure chamber within t he limits of the experimental errors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of ionizing radiation emitted from the cesium-137 and cobalt-60 sources using electrochemical superoxide anion sensor in the aqueous medium

Widespread use of ionizing radiation in medicine, industry, agriculture, education and research, the increasing production of nuclear waste and nuclear incidents, has exposed humans and organisms to this radiation. Despite the benefits of ionizing radiation, these beams can cause serious damage to living systems. Hence, the need for radiation protection actions requires accurate, fast, inexpens...

متن کامل

Evaluation of dosimetry a performance parameter for a homemade farmer-type ionization chamber according to IEC60731

Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter    of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...

متن کامل

Comparison Between the NIST and the KEBS for the Determination of Air Kerma Calibration Coefficients for Narrow X-Ray Spectra and 137Cs Gamma-Ray Beams

Air kerma calibration coefficients for a reference class ionization chamber from narrow x-ray spectra and cesium 137 gamma-ray beams were compared between the National Institute of Standards and Technology (NIST) and the Kenya Bureau of Standards (KEBS). A NIST reference-class transfer ionization chamber was calibrated by each laboratory in terms of the quantity air kerma in four x-ray referenc...

متن کامل

Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy

Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...

متن کامل

Investigation of the air kerma response of spherical ionization chambers for unfolded pulse height distributions of (60)Co and (137)Cs using the EGS4 Monte Carlo code.

Data required for the determination of the absolute air kerma rate for (60)Co and (137)Cs gamma-rays using spherical cavity chambers were calculated using the EGS4 Monte Carlo system. Mass energy-absorption coefficient ratio and the stopping power ratio were calculated for a 10 cm(3) primary standard graphite-walled ionization chamber from the unfolded energy pulse height distributions of (60)C...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006