The effects of distal interlocking screws on torsional stability in three-part intertrochanteric hip fractures

نویسندگان

  • Bryan G Vopat
  • Patrick M Kane
  • P Kaveh Mansuripur
  • David Paller
  • Sarath Koruprolu
  • Emily Abbood
  • Christopher T Born
چکیده

OBJECTIVE Many surgeons currently use long cephomedullary nails for the treatment of intertrochanteric fractures. The optimal indications for deploying distal interlocks are still debatable. This study examined the torsional biomechanical properties of 3-part intertrochanteric femur fractures in a cadaveric bone model using two different distal fixation strategies, an unlocked long cephalomedullary nail versus a dynamically locked nail. Our hypothesis is that a long cephalomedullary nail does not require distal locking fixation when used for treatment of a 3-part intertrochanteric fracture. METHODS Five matched pairs of cadaveric femora were randomly assigned to one of two distal fixation treatment groups; a single distal interlock screw placed in the dynamic orientation or no distal fixation. A 3-part intertrochanteric fracture was produced. Specimens were potted and mounted in a double gimbal fixture facilitating unconstrained motion in the sagittal and coronal planes. Specimens were cyclically loaded dynamically in both internal and external rotation. Range of motion, internal and external rotation stiffness, torsion stiffness, torsion yield and ultimate torsion magnitude were calculated. RESULTS The samples instrumented with a distal locking screw reported statistically greater external rotational stiffness than the unlocked samples in nondestructive testing. The results of the destructive data demonstrated no statistical difference between the locked and unlocked group with regard to yield torque (p = 0.282), peak torque (p = 0.340), stiffness (p = 0.220), displacement at yield torque (p = 0.0605), and displacement at peak torque (p = 0.280). CONCLUSION Distal locking of a long cephalomedullary nail increases the stiffness of the nail-femur construct in a 3-part biomechanical fracture model. However, our testing illustrates that an unlocked construct will tolerate at least equal stress before catastrophic failure in a torsional loading model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques

Background: At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. Methods: In this randomi...

متن کامل

Biomechanical evaluation of the percutaneous compression plating system for hip fractures.

OBJECTIVE To investigate the biomechanical properties of the percutaneous compression plating system for intertrochanteric hip fractures. DESIGN A biomechanical laboratory investigation on human cadaveric upper femora was conducted. SETTING Biomechanical laboratory. PATIENTS Sixteen femora from cadavers of patients aged 60 to 85 years. INTERVENTION An intertrochanteric fracture was perf...

متن کامل

The Role of Biplanar Distal Locking in Intramedullary Nailing of Tibial Shaft Fractures

Background: To compare the union times of the uncomplicated tibial shaft fractures, which were distally locked by twocoronal and one sagittal screws and by only two coronal screws.Methods: 45 patients with tibial shaft treated with intramedullary nailing included in this study. 23 of 45 fractureswere treated with uniplanar two distal interlocking (Group 1) and 22 fractures were treated with bip...

متن کامل

Intramedullary Nails Result in More Reoperations Than Sliding Hip Screws in Two-part Intertrochanteric Fractures

BACKGROUND Sliding hip screws (SHSs) and intramedullary (IM) nails are well-documented implants for simple two-part intertrochanteric fractures; however, there is no consensus regarding which type of implant is better. QUESTIONS/PURPOSES We asked whether patients with simple two-part intertrochanteric fractures treated with IM nailing had (1) a lower reoperation rate and (2) less pain and bet...

متن کامل

Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing

Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experimen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2015