Optimized plasma preparation is essential to monitor platelet-stored molecules in humans
نویسندگان
چکیده
Platelets store a plethora of different molecules within their granules, modulating numerous pathways, not only in coagulation, but also in angiogenesis, wound healing, and inflammatory diseases. These molecules get rapidly released upon activation and therefore represent an easily accessible indirect marker for platelet activation. Accurate analysis of platelet-derived molecules in the plasma requires appropriate anticoagulation to avoid in vitro activation and subsequent degranulation of platelets, potentially causing artificially high levels and masking biologically relevant differences within translational research studies. However, there is still enormous heterogeneity among anticoagulants used to prevent unwanted platelet activation, so that plasma levels reported for platelet granule contents range over several orders of magnitude. To address this problem and to define the most robust method of plasma preparation to avoid in vitro platelet activation during processing, we compared plasma concentrations of the three platelet-stored factors thrombospondin (TSP-1), platelet factor 4 (PF4), and soluble P-selectin (sCD62P) between human blood samples anticoagulated with either citrate-theophylline-adenosine-dipyridamole (CTAD), acid-citrate-dextrose (ACD), citrate, ethylenediaminetetraacetic acid (EDTA) or heparin. Additionally, we assessed the effect of storage temperature and time between blood drawing and sample processing within the differentially anticoagulated samples. Our data strongly support the use of CTAD as anticoagulant for determining plasma concentrations of platelet-stored molecules, as anticoagulation with heparin or EDTA led to a 12.4- or 8.3-fold increase in plasma levels of PF4, respectively. Whereas ACD was similar effective as CTAD, citrate only showed comparable PF4 plasma levels when plasma was kept at 4°C. Moreover, blood sampling with CTAD as anticoagulant resulted in the most reproducible values, even when samples were processed at ambient temperature or after storage over 6 hours. In the latter case, anticoagulation with heparin or EDTA led to artificially high plasma levels indicative of in vitro platelet activation. Therefore, we want to raise scientific awareness for choosing CTAD as optimal anticoagulant for the detection of platelet-stored molecules in plasma.
منابع مشابه
An Overview on Platelet-derived Microparticles in Platelet Concentrates: blood collection, method preparation and storage
Preparations of platelet concentrates (PCs) that are stored under blood bank conditions and used for transfusion purposes, appear to be enriched in platelet derived-microparticles (PMPs) with high coagulant activity that may change platelet efficacy and safety issues. High shear stress could cause shedding of PMPs from the platelet plasma membrane, platelet aggregation, and activation of the co...
متن کاملEvaluation of Biochemical Parameters of Platelet Concentrates Stored in Plasma or in A Platelet Additive Solution (Composol)
Abstract Objective Removing plasma from the platelet concentrate (PC) medium could be an effective way to increase the safety of this product. The goal of this study was to compare PC stored in plasma or in an additive solution (Composol) with in vitro testing. Materials and Methods Fifty-four single donor PCs were prepared from Iranian Blood Transfusion Organization (IBTO). Each PC unit wa...
متن کاملتاثیر فیلتراسیون پیش از ذخیره کردن بر فعال شدن پلاکتها در فراوردههای پلاکتی
Preparation conditions and platelet storage for transfusion may cause platelet activation, which contributes to decreased ability of stored platelet to function and survive in vivo after transfusion compared with that seen with freshly prepared platelets. Using flowcytometry, we investigated platelet membrane expression of CD62P, CD63 in platelet stored for up to 3 days under standard blood ba...
متن کاملEvaluation of microRNAs; mir223, mir222 and mir92a levels in the Platelet-derived microparticles in the Platelet concentrates produced by Platelet Rich Plasma method during storage
Abstract Background and Objectives Platelets release microparticles containing cellular components, including microRNAs, during storage. Assessment of these microRNAs is one of the markers for evaluation of platelet storage lesions. The aim of the present study was to evaluate the level of changes in the expression of mir-223, mir-92a and mir-222 during storage in platelets prepared by platele...
متن کاملApplication of platelet-rich plasma and other platelet-derivative products in Iranian studies
Introduction: The use of platelet products such as platelet-rich plasma (PRP) as a component of regenerative medicine has been on the rise in Iran like other countries. We aimed to go over the current published work of Iranian researchers on platelet products, while performing qualitative and quantitative assessments about them. Materials and Methods: This study was performed as review study. T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2017