Method development in membrane inlet mass spectrometry. Air analysis and desorption techniques
نویسنده
چکیده
Membrane inlet mass spectrometry (MIMS) is an established technique for the analysis of volatile organic compounds in aqueous solutions and in air. A thin membrane is the only interface between a liquid or gaseous sample at atmospheric pressure and the vacuum of a mass spectrometer. Since its introduction about 35 years ago MIMS has been applied mainly in biochemistry and environmental analysis. In this work the applicability of MIMS in the analysis of volatile organic compounds (VOCs) in water samples was investigated, and improved MIMS methods for the analysis of VOCs in air samples were constructed. The possibilities of MIMS for the analysis of polar and/or semivolatile compounds in aqueous samples were enhanced with novel techniques. It was demonstrated that the MIMS method is comparable with static headspace gas chromatography and purge&trap gas chromatography-mass spectrometry methods in the analysis of VOCs in water samples. The MIMS method was also shown to be very suitable for on-site measurement of water samples in a mobile laboratory. A membrane inlet mass spectrometric method was developed for the analysis of volatile organic compounds, especially volatile sulfur compounds, in air samples. The method is very sensitive, i.e. detection limits are at sub or low μg/m levels, and also very rapid: it is possible to analyze even 50 to 100 samples in one hour with a thin polydimethylsiloxane membrane because response times are only a few seconds. When MIMS is combined with a temperature-programmed desorption (TPD) technique it is possible to achieve
منابع مشابه
Remote Monitoring of Volatile Organic Compounds in Water by Membrane Inlet Mass Spectrometry
16.
متن کاملنمونه برداری و تعیین مقدار کلروبنزن در هوا با روش میکرواستخراج فاز جامد-گاز کروماتوگرافی طیف بین جرمی
Abstract Background and aims: The chlorobenzene is an intermediate chemical that is used in the production of commodities such as herbicides, dyestuffs, and rubber and Causes neurological complications and effects on the respiratory tract. In this research solid phase micro extraction (SPME) was used for the sampling of chlorobenzene in air. The optimum conditions for analysis with gas chrom...
متن کاملPressure-assisted capillary electrophoresis electrospray ionization mass spectrometry for analysis of multivalent anions.
We describe a method, based on pressure-assisted capillary electrophoresis coupled to electrospray ionization mass spectrometry (PACE/ESI-MS), that allows the simultaneous and quantitative analysis of multivalent anions, such as citrate isomers, nucleotides, nicotinamide-adenine dinucleotides, and flavin adenine dinucleotide, and coenzyme A (CoA) compounds. Key to the analysis was using a nonch...
متن کاملEasily fabricated ion source for characterizing mixtures of organic compounds by direct analysis in real time mass spectrometry
The increasing use of atmospheric pressure mass spectrometry has led to the development of many ambient ionization sources, for which sampling versatility and low cost are desired features. One such recent ambient ionization method is direct analysis in real time mass spectrometry (DART-MS), which has proven to be well suited to the analysis of native samples of both simple and complex natures....
متن کاملMembrane Inlet-based Portable Time-of-flight Mass Spectrometer for Analysis of Air Samples
A miniaturized time-of-flight mass spectrometer with an electron impact ionization source and sheet membrane introduction has been developed. The advantages and features of this mass spectrometer include high sensitivity, simple structure, low cost, compact volume with field portability, and ease of operation. A mass resolution of 400 at m/z 78 has been obtained with a 25 cm flight path length....
متن کامل