Assessment of the impact of applying attenuation correction on the accuracy of activity recovery in Tc99m-ECD brain SPECT of healthy subject using Statistical Parametric Mapping (SPM)

نویسندگان

  • Faezeh Vedaei
  • Alireza Kamali asl
  • Faraz Kalantari
  • Mojtaba Ansari
  • Mohammad Reza Ay
چکیده

Introduction: Photon attenuation in tissues is the primary physical degrading factor limiting both visual qualitative interpretation and quantitative analysis capabilities of reconstructed Single Photon Emission Computed Tomography (SPECT) images. The aim of present study was to investigate the effect of attenuation correction on the detection of activation foci following statistical analysis with SPM. Methods: The study population consisted of twenty normal subjects (11 male, 9 female, and age 30-40 years). SPECT images were reconstructed using filter back projection and attenuation correction was done by the Chang method. The SPECT imagings was obtained 20 min after intravenous injection of 740-1110 MBq (20-30 mCi) of Tc99m-ECD and were acquired on 128×128 matrices with a 20% symmetric energy window at 140 keV. These data publicly distributed by the Society of Nuclear Medicine of Toronto Hospital. The data was standardized with respect to the Montreal Neurological Institute (MNI) atlas with a 12 parameter affine transformations. Images were then smoothed by a Gaussian filter of 10 mm FWHM. Significance differences between SPECT images were estimated at every voxel using statistical t-test and p-value as the significant criteria was set at 0.05. Results: The contrast comparing non attenuation corrected to attenuation corrected images suggest that regional brain perfusion activity increase in the cerebrum, frontal (T-value 12.06) , temporal (T-value 10.63) and occipital (T-value 9.31) lobe and decrease in the sub-lobar, extra-nuclear (T-value 17.46) and limbic lobe, posterior cingulate (T-value 17.46) before attenuation correction compare with attenuation correction. Conclusion: It can be concluded that applying attenuation correction in brain SPECT can effectively improve the accuracy of the detection of activation area (p<0.05).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the impact of applying attenuation correction on the accuracy of activity recovery in Tc99m-ECD brain SPECT of healthy subject using Statistical Parametric Mapping (SPM)

Introduction: Photon attenuation in tissues is the primary physical degrading factor limiting both visual qualitative interpretation and quantitative analysis capabilities of reconstructed Single Photon Emission Computed Tomography (SPECT) images. The aim of present study was to investigate the effect of attenuation correction on the detection of activation foci following statistical analysis w...

متن کامل

Review of transmission scanning configurations in cardiac SPECT

The diagnostic accuracy of single photon emission computed tomography (SPECT) is profoundly influenced by attenuation phenomenon. Soft tissue attenuation degrades cardiac SPECT image quality, thereby decreasing the possibility of the detection of the lesions. A variety of correction techniques based on different assumptions have been used to reduce the impact of attenuation. Several types of sy...

متن کامل

Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3‐dimensional brain phantom

Objective: The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. It was filled with 123I solution (20...

متن کامل

Evaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom

Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...

متن کامل

Evaluation of attenuation correction process in cardiac SPECT images

  Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012