Dependence of free thyroxine estimates obtained with equilibrium tracer dialysis on the concentration of thyroxine-binding globulin.
نویسندگان
چکیده
Some equilibrium dialysis determinations of free thyroxine (T4) vary directly with thyroxine-binding globulin (TBG) concentration. This apparent TBG dependence has been limited to methods involving radiolabeled T4 added to the dialysis system (tracer dialysis). In this study we compared tracer dialysis with direct dialysis for determining free T4 and obtained the following results (mean +/- SD) for patients with hypothyroxinemia of nonthyroidal illness (23.8 +/- 10.7 vs 24.2 +/- 10.9 pmol/L, P greater than 0.8), patients with congenital TBG deficiency (11.4 +/- 2.2 vs 16.2 +/- 7.1 pmol/L, P greater than 0.05), normal control subjects (32.7 +/- 6.5 vs 18.5 +/- 5.8 pmol/L, P less than 0.001), and pregnant women (31.2 +/- 8.7 vs 12.1 +/- 2.6 pmol/L, P less than 0.001). Direct dialysis determinations were independent of TBG and total T4. Tracer determinations were greater than direct determinations in normals, a discrepancy that increased in pregnancy. Tracer determinations correlated significantly with total T4 and TBG concentrations (P less than 0.001). TBG and total T4 dependence in the tracer method was attributable to small overestimations of the free fraction of T4. Similar overestimations multiplied by increasing total T4 concentrations resulted in greater errors. Relative to results for normal sera, the tracer method overestimated free T4 when total T4 was increased and underestimated free T4 when total T4 was decreased.
منابع مشابه
Binding of Thyroxine by Human Serum Albumin
In previous work from this laboratory (1) studies on equilibrium dialysis were carried out to determine the binding constants for the interaction of human serum albumin with thyroxine and its analogs. The classical technique of equilibrium dialysis as described by Scatchard and others (2-6) was employed. At present it seems clear that thyroxine in human serum migrates to at least three differen...
متن کاملBinding of Thyroxine by Serum Proteins Evaluated by Equilibrum Dialysis and Electrophoretic Techniques. Alterations in Nonthyroidal Illness.
Considerable evidence suggests that the concentration of free thyroxine, circulating unbound to serum proteins, is more closely relattd to a subject's thyroidal status than is the concentration of total thyroxine (1). Because of the intense binding of thyroxine by the serum proteins, the concentration of free thyroxine is very small and not measurable by conventional chemical methods. Robbins a...
متن کاملDetermination of free thyroxine in serum by low-temperature equilibrium dialysis.
Equilibrium dialysis of thyroxine (14) in diluted serum at low temperature gives consistent and reproducible values for the dialyzable fraction (DF) of this hormone. The quantity of serum required for the determination is minimized by dilution, which is technically advantageous. Variations caused by temperature, dialysis time, dilution of serum, buffer system, and stability of 125l.T4 could be ...
متن کاملThyroxine-protein interactions. Interaction of thyroxine and triiodothyronine with human thyroxine-binding globulin.
The effect of temperature on the binding of thyroxine and triiodothyronine to thyroxine-binding globulin has been studied by equilibrium dialysis. Inclusion of ovalbumin in the dialysis mixture stabilized thyroxine-binding globulin against losses in binding activity which had been found to occur during equilibrium dialysis. Ovalbumin by itself bound the thyroid hormones very weakly and its bind...
متن کاملOn the albumin dependence of measurements of free thyroxin. I. Technical performance of seven methods.
We evaluated three one-step (analog) and two two-step radioimmunoassay for free thyroxin (FT4), and a FT4 index calculated from the total T4 (TT4) and thyroxin-binding globulin (TBG) ratio for technical performance, for correlation with the reference FT4 method (equilibrium dialysis), and for dependence on TBG and albumin concentrations. The one-step methods (Amerlex, Coat-A-Count, and GammaCoa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 38 7 شماره
صفحات -
تاریخ انتشار 1992