Early catastrophic failure of Birmingham acetabular dysplasia cup in revision arthroplasty: a case report
نویسندگان
چکیده
INTRODUCTION Revision acetabulum arthroplasty is one of the common procedures, which has been on the rise recently. Many implants are available in the market with variable results. Aseptic loosening is the most common indication for revision acetabulum arthroplasty. Birmingham dysplasia cup has been used occasionally in these complex procedures. We know that these implants have provided good results in resurfacing dysplastic hips with bone loss. Literature review failed to answer whether these implants were as effective in revision acetabulum arthroplasty. CASE PRESENTATION We herby, present a case of revision acetabulum arthroplasty performed with Birmingham dysplasia acetabular cup, which unfortunately failed within a period of eight months. Surgical technique appeared to be adequate. On further analysis, significant differences were identified between dysplastic hips with bone loss and revision hips with bone loss. CONCLUSION Therefore results obtained with dysplasia cups in resurfacing dysplastic hips does not seem to be applicable to revision hip arthroplasty. Hence these cups should be restricted to primary arthroplasty.
منابع مشابه
Catastrophic fracture of a stable metal acetabular component.
Various modes of failure of primary and revision total hip arthroplasty have been well documented in the literature over the past 30 years. Concerns over polyethylene wear, osteolysis, and hypersensitivity reactions leading to component loosening and early revision have been evaluated and reported in the literature. Routine follow-up is important to monitor for postoperative issues that might l...
متن کاملHip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملFatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملEarly Clinical Outcomes with a 3-D Porous Titanium Acetabular Cup
Cementless acetabular components are associated with a significant incidence of polyethylene wear and secondary osteolysis. 3-dimentional (3-D) porous coating and enhanced shell to a liner fixation are expected to reduce the polyethylene wear and to increase the longevity of an acetabular cup. The authors report the early clinical outcome with a cementless acetabular cup, Regenerex Ringloc+ (Zi...
متن کاملPseudotumour Complicated by Implant Loosening One Year After revision Ceramic on Metal Total Hip Arthroplasty: A Case Report
INTRODUCTION Pseudotumor is not an uncommon complication after total hip arthroplasty (THA). This can occur in relationship to different bearing surfaces of head and liner ranging from soft to hard articulation. There is wide spectrum of presentation from asymptomatic to implant failure. CASE REPORT We report a case of pseudotumor formation with acetabular cup aseptic loosening after revision...
متن کامل