Compression-sensitive magnetic resonance elastography.

نویسندگان

  • Sebastian Hirsch
  • Frauke Beyer
  • Jing Guo
  • Sebastian Papazoglou
  • Heiko Tzschaetzsch
  • Juergen Braun
  • Ingolf Sack
چکیده

Magnetic resonance elastography (MRE) quantifies the shear modulus of biological tissue to detect disease. Complementary to the shear elastic properties of tissue, the compression modulus may be a clinically useful biomarker because it is sensitive to tissue pressure and poromechanical interactions. In this work, we analyze the capability of MRE to measure volumetric strain and the dynamic bulk modulus (P-wave modulus) at a harmonic drive frequency commonly used in shear-wave-based MRE. Gel phantoms with various densities were created by introducing CO2-filled cavities to establish a compressible effective medium. The dependence of the effective medium's bulk modulus on phantom density was investigated via static compression tests, which confirmed theoretical predictions. The P-wave modulus of three compressible phantoms was calculated from volumetric strain measured by 3D wave-field MRE at 50 Hz drive frequency. The results demonstrate the MRE-derived volumetric strain and P-wave modulus to be sensitive to the compression properties of effective media. Since the reconstruction of the P-wave modulus requires third-order derivatives, noise remains critical, and P-wave moduli are systematically underestimated. Focusing on relative changes in the effective bulk modulus of tissue, compression-sensitive MRE may be useful for the noninvasive detection of diseases involving pathological pressure alterations such as hepatic hypertension or hydrocephalus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo measurement of volumetric strain in the human brain induced by arterial pulsation and harmonic waves.

Motion-sensitive phase contrast magnetic resonance imaging and magnetic resonance elastography are applied for the measurement of volumetric strain and tissue compressibility in human brain. Volumetric strain calculated by the divergence operator using a biphasic effective-medium model is related to dilatation and compression of fluid spaces during harmonic stimulation of the head or during int...

متن کامل

Towards compression-sensitive magnetic resonance elastography of the liver: sensitivity of harmonic volumetric strain to portal hypertension.

PURPOSE To assess induced oscillating volumetric strain as a biomarker for intrahepatic blood pressure abnormalities. MATERIALS AND METHODS Harmonic vibrations of 25 and 50 Hz frequency were induced in the liver and measured by fast 3D vector field magnetic resonance elastography (MRE), followed by processing of the decomposed curl (shear) and divergence (compression) fields. After an initial...

متن کامل

Quantitative shear wave magnetic resonance elastography: comparison to a dynamic shear material test.

Magnetic resonance elastography (MRE), a phase contrast MRI technique, images the propagation of applied mechanical waves in tissue, allowing shear stiffness to be quantified in vivo. This MRE technique has been validated with static mechanical compression tests. Dynamic mechanical analysis (DMA) may be a more appropriate comparison to MRE because it directly measures the shear modulus dynamica...

متن کامل

A possible clinical tool to depict muscle elasticity mapping using magnetic resonance elastography.

INTRODUCTION Characterization of muscle elasticity will improve the diagnosis and treatment of muscle disorders. The purpose is to compare the use of magnetic resonance elastography (MRE) and ultrasound elastography (USE) techniques to elucidate the MRE cartography of thigh muscles. METHODS Both elastography techniques were performed on 5 children and 7 adults. Quantitative (MRE) and qualitat...

متن کامل

Vibration-synchronized magnetic resonance imaging for the detection of myocardial elasticity changes.

Vibration synchronized magnetic resonance imaging of harmonically oscillating tissue interfaces is proposed for cardiac magnetic resonance elastography. The new approach exploits cardiac triggered cine imaging synchronized with extrinsic harmonic stimulation (f = 22.83 Hz) to display oscillatory tissue deformations in magnitude images. Oscillations are analyzed by intensity threshold-based imag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 58 15  شماره 

صفحات  -

تاریخ انتشار 2013