Narrowing Microfluid Width In Microchannel Using Air Boundaries

نویسندگان

  • Sang Uk Son
  • Seung S. Lee
چکیده

A novel method for narrowing microfluid width in microchannel is presented by utilizing of air boundaries of which inflation direction is perpendicular to microfluid flow. The air boundaries are generated by heating water with microheater. The microfluid width of 300 pm can be focused and maintained as up to 22 pm which is near cell size without affecting cell or microchannel structure. The narrowed width is regulated by pressure in the air boundaries and flow velocity of microfluid. The method can enhance sensitivity in flow cytometry by placing the air boundaries near sensing area and guiding cells.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tuning microchannel wettability and fabrication of multiple-step Laplace valves.

By using characteristics of titania nanoparticles, a patterning and tuning method of microchannel surface wettability was developed for microfluid control. Titania modification of a microchannel provided a nanometer-sized surface roughness and the subsequent hydrophobic treatment made the surface superhydrophobic. Photocatalytic decomposition of the coated hydrophobic molecules was used to patt...

متن کامل

Waste water ammonia stripping intensification using microfluidic system

This paper reports the results of experimentally removing ammonia from synthetically prepared ammonia solution using a micro scale mixing loop air stripper. Effects of various operational parameters (such as: pH, air flow rate, wastewater flow rate and initial ammonia concentration) were evaluated. By increasing the pH from 10 to 12.25 the amount of KLa increased from 0.26 to 0.73 hr-1. A consi...

متن کامل

Experimental study of convective heat transfer coefficient of MgO nanofluid in a cylindrical microchannel heat sink

Convective heat transfer of MgO-water nanofluid in a microchannel heat sink is experimentally investigated in various concentrations of 0.01, 0.05, 0.1, and 0.6 wt%. The microchannel consisted of 48 parallel rectangular cross section channels with the height of 800 µm, width of 524 µm and length of 52 mm. A well stability duration (ca. 1 month) was resulted by a 180 min ultra-sonication of the ...

متن کامل

A Biomedical Application by Using Optimal Fuzzy Sliding-Mode Control

The development of biochips is a major thrust of the rapidly growing biotechnology industry. Research on biomedical or biochemical analysis miniaturization and integration has made explosive progress by using biochips recently. For example, capillary electrophoresis (CE), sample preconcentration, genomic DNA extraction, and DNA hybridization have been successfully miniaturized and operated in a...

متن کامل

Imaging X-Ray Fluorescence Using Microchannel Plate (MCP) Optics

X-ray fluorescence imaging is a widely used, nondestructive method for determining the distribution and relative concentration of metals within a sample. To create a two-dimensional map of an image, x-rays are usually sent through a 25-250 μm wide aperture, then point by point an image is scanned. Microchannel plates contain an array of tiny holes that can be used to collimate x-rays fluorescin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003