Evaluation of an Active Humidification System for Inspired Gas
نویسندگان
چکیده
OBJECTIVES The effectiveness of the active humidification systems (AHS) in patients already weaned from mechanical ventilation and with an artificial airway has not been very well described. The objective of this study was to evaluate the performance of an AHS in chronically tracheostomized and spontaneously breathing patients. METHODS Measurements were quantified at three levels of temperature (T°) of the AHS: level I, low; level II, middle; and level III, high and at different flow levels (20 to 60 L/minute). Statistical analysis of repeated measurements was performed using analysis of variance and significance was set at a P<0.05. RESULTS While the lowest temperature setting (level I) did not condition gas to the minimum recommended values for any of the flows that were used, the medium temperature setting (level II) only conditioned gas with flows of 20 and 30 L/minute. Finally, at the highest temperature setting (level III), every flow reached the minimum absolute humidity (AH) recommended of 30 mg/L. CONCLUSION According to our results, to obtain appropiate relative humidity, AH and T° of gas one should have a device that maintains water T° at least at 53℃ for flows between 20 and 30 L/m, or at T° of 61℃ at any flow rate.
منابع مشابه
Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers.
OBJECTIVE During invasive mechanical ventilation, inspired gases must be humidified. We previously showed that high ambient temperature greatly impaired the hygrometric performance of heated wire-heated humidifiers. The aim of this bench and clinical study was to assess the humidification performance of passive and active heat and moisture exchangers (HMEs) and the impact of ambient temperature...
متن کاملHumidification on Ventilated Patients: Heated Humidifications or Heat and Moisture Exchangers?
The normal physiology of conditioning of inspired gases is altered when the patient requires an artificial airway access and an invasive mechanical ventilation (IMV). The endotracheal tube (ETT) removes the natural mechanisms of filtration, humidification and warming of inspired air. Despite the noninvasive ventilation (NIMV) in the upper airways, humidification of inspired gas may not be optim...
متن کاملA new prototype of an electronic jet-ventilator and its humidification system
BACKGROUND: Adequate humidification in long-term jet ventilation is a critical aspect in terms of clinical safety. AIM: To assess a prototype of an electronic jet-ventilator and its humidification system. METHODS: Forty patients with respiratory insufficiency were randomly allocated to one of four groups. The criterion for inclusion in this study was respiratory insufficiency exhibiting a Murra...
متن کاملHumidification during invasive and noninvasive mechanical ventilation: 2012.
We searched the MEDLINE, CINAHL, and Cochrane Library databases for articles published between January 1990 and December 2011. The update of this clinical practice guideline is based on 184 clinical trials and systematic reviews, and 10 articles investigating humidification during invasive and noninvasive mechanical ventilation. The following recommendations are made following the Grading of R...
متن کاملHumidification in the intensive care unit.
In summary, current data indicate that body temperature cannot be controlled efficiently by changing inspired gas temperature. Inspired gas temperature should therefore be maintained at 32 degrees C to 34 degrees C for intubated patients and other efforts should be made to optimize body temperature.
متن کامل