Mechanosensitive afferent units in the lumbar posterior longitudinal ligament.

نویسندگان

  • M Sekine
  • T Yamashita
  • T Takebayashi
  • N Sakamoto
  • Y Minaki
  • S Ishii
چکیده

STUDY DESIGN The mechanosensitive afferent units in the lumbar posterior longitudinal ligament were investigated in an animal model using an electrophysiologic technique. OBJECTIVES The objectives of this study were to identify the mechanosensitive receptive fields in the lumbar posterior longitudinal ligament and to investigate their distribution and characteristics. SUMMARY OF BACKGROUND DATA The lumbar posterior longitudinal ligament has a nerve network originating from the sinuvertebral nerve. These fibers are thin, and most of their terminals are free nerve endings. Some immunohistochemical studies have indicated that they are immunoreactive to calcitonin gene-related peptide and/or substance P, suggesting a nociceptive function. Most of these studies investigated morphologic aspects, and there have been few studies employing electrophysiologic techniques to examine mechanosensitive units. METHODS We used 13 adult cats. They were anesthetized and then laminectomy was performed. The L5 and L6 dorsal rootlets were draped over a recording electrode. To investigate the receptive fields in the posterior longitudinal ligament, afferent impulses were evoked by mechanical stimulation with a glass probe. When the receptive fields were located, they were stimulated electrically to obtain conduction velocity and were stimulated with a set of 17 nylon filaments to determine their mechanical thresholds. RESULTS Thirteen units were identified in the lumbar posterior longitudinal ligament. The majority of the units were located around the intervertebral disc level of the posterior longitudinal ligament. The mean mechanical threshold was 47.04 +/- 15.25 g. According to the conduction velocities of the units, 12 units were classified into Group III (0.5-2.5 m/sec) and one unit into Group IV (2.5-20 m/sec). CONCLUSION Mechanosensitive units classified into Group III or Group IV and with a high mechanical threshold (>7.0 g) were thought to act as nociceptive units. All units identified in this study satisfied these criteria. Our result suggests that afferent fibers from the lumbar posterior longitudinal ligament have a principally nociceptive function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanosensitive afferent units in the lateral ligament of the ankle.

We have studied the mechanosensitive afferent units in the lateral ligament of the ankle of the cat, with reference to the causes of lateral instability after injury, using electrophysiological recording from the lumbar dorsal rootlets. We identified 30 mechanosensitive units in the lateral ligament; 28 (93%) were located near the attachment to the fibula and calcaneus, which included both low-...

متن کامل

Ossification of the posterior longitudinal and yellow ligaments on the lumbar spine.

Ossification of the posterior longitudinal ligament and ossification of the yellow ligament are the main causes of spinal canal stenosis. This article describes a case of ossification of the posterior longitudinal and yellow ligaments on the lumbar spine. The patient presented with gradually worsening left lower-extremity ache and pain. The deep tendon reflex was hyperreflexia in the lower extr...

متن کامل

Ossification of the posterior longitudinal ligament: a clinico-radiological study of 74 cases.

A clinico-radiological analysis of 74 cases of ossification of the posterior longitudinal ligament is reported. Eighteen cases (24%) were asymptomatic or only had neck or shoulder pain; 16 cases (22%) showed signs of radiculopathy, and the remaining 40 cases (54%) had myelopathy. Ossification of the posterior longitudinal ligament developed most frequently at C5, and was rare in thoracic and lu...

متن کامل

Preserving Posterior Complex Can Prevent Adjacent Segment Disease following Posterior Lumbar Interbody Fusion Surgeries: A Finite Element Analysis

OBJECTIVE To investigate the biomechanical effects of the lumbar posterior complex on the adjacent segments after posterior lumbar interbody fusion (PLIF) surgeries. METHODS A finite element model of the L1-S1 segment was modified to simulate PLIF with total laminectomy (PLIF-LAM) and PLIF with hemilaminectomy (PLIF-HEMI) procedures. The models were subjected to a 400N follower load with a 7....

متن کامل

Ossification of the posterior longitudinal ligament.

The authors described 21 patients aged 37 to 83 with ossification of the posterior longitudinal ligament (10 with ischemic myelopathy, 6 with aftermaths of a trauma of the cervical spine, and 5 with the radicular syndrome on the basis of vertebral osteochondrosis. X-ray signs of three types of ossification of the posterior longitudinal ligament were defined and specified: linear, curved and mix...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 26 14  شماره 

صفحات  -

تاریخ انتشار 2001