Comparison of visual biofeedback system with a guiding waveform and abdomen-chest motion self-control system for respiratory motion management

نویسندگان

  • Yujiro Nakajima
  • Noriyuki Kadoya
  • Takayuki Kanai
  • Kengo Ito
  • Kiyokazu Sato
  • Suguru Dobashi
  • Takaya Yamamoto
  • Yojiro Ishikawa
  • Haruo Matsushita
  • Ken Takeda
  • Keiichi Jingu
چکیده

Irregular breathing can influence the outcome of 4D computed tomography imaging and cause artifacts. Visual biofeedback systems associated with a patient-specific guiding waveform are known to reduce respiratory irregularities. In Japan, abdomen and chest motion self-control devices (Abches) (representing simpler visual coaching techniques without a guiding waveform) are used instead; however, no studies have compared these two systems to date. Here, we evaluate the effectiveness of respiratory coaching in reducing respiratory irregularities by comparing two respiratory management systems. We collected data from 11 healthy volunteers. Bar and wave models were used as visual biofeedback systems. Abches consisted of a respiratory indicator indicating the end of each expiration and inspiration motion. Respiratory variations were quantified as root mean squared error (RMSE) of displacement and period of breathing cycles. All coaching techniques improved respiratory variation, compared with free-breathing. Displacement RMSEs were 1.43 ± 0.84, 1.22 ± 1.13, 1.21 ± 0.86 and 0.98 ± 0.47 mm for free-breathing, Abches, bar model and wave model, respectively. Period RMSEs were 0.48 ± 0.42, 0.33 ± 0.31, 0.23 ± 0.18 and 0.17 ± 0.05 s for free-breathing, Abches, bar model and wave model, respectively. The average reduction in displacement and period RMSE compared with the wave model were 27% and 47%, respectively. For variation in both displacement and period, wave model was superior to the other techniques. Our results showed that visual biofeedback combined with a wave model could potentially provide clinical benefits in respiratory management, although all techniques were able to reduce respiratory irregularities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Commissioning and quality assurance for a respiratory training system based on audiovisual biofeedback

A respiratory training system based on audiovisual biofeedback has been implemented at our institution. It is intended to improve patients' respiratory regularity during four-dimensional (4D) computed tomography (CT) image acquisition. The purpose is to help eliminate the artifacts in 4D-CT images caused by irregular breathing, as well as improve delivery efficiency during treatment, where resp...

متن کامل

Generating the Visual Biofeedback Signals Applicable to Reduction of Wrist Spasticity: A Pilot Study on Stroke Patients

Introduction: Application of biofeedback techniques in rehabilitation has turned into an exciting research area during the recent decade. Providing an appropriate visual or auditory biofeedback signal is the most critical requirement of a biofeedback technique. In this regard, changes in Surface Electromyography (SEMG) signals during wrist movement can be used to generate an indictable visual b...

متن کامل

Effects of Visual Biofeedback Therapy on Postural Balance of Stroke Patients

Purpose: Postural balance deficit is one of the common post-stroke disabilities. Providing visual biofeedback while balance activities are performed is a way to improve postural balance disorders following stroke. But among the research published, there is incoherency about the positive effects of visual biofeedback therapy. The purpose of this study was to investigate the effects of usin...

متن کامل

WE-G-213CD-07: Enhancing Respiratory Motion Prediction Accuracy Using Audiovisual (AV) Biofeedback.

PURPOSE Prediction of respiratory-related tumor motion is hampered by irregularities present in the patient breathing patterns. Audiovisual (AV) biofeedback reduces irregularities, thereby producing a less complex breathing pattern. The aim of this project is to improve respiratory motion prediction accuracy using an AV biofeedback system. METHODS An AV biofeedback system combined with real-t...

متن کامل

SU-D-BRA-04: Improvement of Diaphragm Motion Reproducibility in MRI Using Audiovisual Biofeedback for Lung Cancer Radiotherapy.

PURPOSE Previous studies have investigated the effect of AV biofeedback on the external respiratory signal reproducibility. This is the first study investigating the effect of AV biofeedback to improve the motion reproducibility of the internal anatomy. The aim of the project is to test the hypothesis that AV biofeedback improves the diaphragm motion reproducibility. METHODS An AV biofeedback...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 57  شماره 

صفحات  -

تاریخ انتشار 2016