Comparison of two commercial methods for measurement of cytomegalovirus load in blood samples after renal transplantation.
نویسندگان
چکیده
A cohort of 77 renal transplant recipients was prospectively studied for comparison of two commercially available cytomegalovirus (CMV) load assays, i.e., the COBAS AMPLICOR CMV Monitor test (Amplicor), using plasma samples, and the Murex Hybrid Capture System (HCS), using whole blood. The manufacturer of the HCS assay changed the version of the test from 1.0 (HCS-1) to 2.0 (HCS-2) after the first 37 patients had been tested. Despite the differences in principle and type of specimen used, the Amplicor and HCS assays gave comparable results. The regression line correlating the HCS-1 assay to the Amplicor assay was similar to that correlating the HCS-2 assay to the Amplicor assay. The HCS results could be converted to Amplicor-equivalent units by using linear-regression equations [log(10) HCS-1 result = 0.49 (log(10) Amplicor result) + 2.58, and log(10) HCS-2 result = 0.61 (log(10) Amplicor result) + 2.18]. The HCS-2 assay appeared to have the lowest detection limit, followed by the Amplicor assay and then the HCS-1 assay. When a sliding scale of cutoff values in Amplicor-equivalent units (>1,000, >2,500, >6,000, >16,000, >40,000, and >100,000 copies/ml) was applied to diagnose CMV disease, similar patterns of sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were observed with the Amplicor and HCS assays. A cutoff value of >40,000 copies/ml has a low sensitivity (Amplicor, 29.4%; HCS, 41.2%) but is specific (Amplicor, 96.7%; HCS, 93.3%) and can be used for the differential diagnosis of CMV disease (PPV, 71.4% [Amplicor] or 63. 6% [HCS]; NPV, 82.9% [Amplicor] or 84.8% [HCS]). A lower cutoff value of >1,000 copies/ml improves the sensitivity (Amplicor, 76.5%; HCS, 82.4%) and has a high NPV (Amplicor, 91.8%; HCS, 94.2%) but, due to the low PPV (Amplicor, 46.2%; HCS, 56%), is useful only for exclusion of CMV disease.
منابع مشابه
Prevalence of Bacterial Urinary Tract Infections in Patients before and after of Kidney Transplantation
Abstract Background and Objective: Urinary tract infections and bacteremia are the major problems in renal transplant patients, which are mostly due to immunesuppressive regimens, surgery, and exposure to the germs in hospital. The aim of this study was to determine the prevalence of bacterial agents in the blood and urine samples of kidney transplant candidates. Material and Methods: In t...
متن کاملAntiviral agents for preventing cytomegalovirus infection in pediatric renal transplant recipients: A systematic review
Background and Objective: Cytomegalovirus (CMV) infections are associated with severe morbidity and mortality in patients, especially pediatric renal transplantation patients. The use of immunosuppressive agents places these patients at the risk of viral infections. As cytomegalovirus infection influences the graft outcome, adopting useful strategies for limiting this virus after transplantatio...
متن کاملIncidence and risk factors for cytomegalovirus in kidney transplant patients in Babol, northern Iran
Background: Cytomegalovirus (CMV) disease is an important cause of death and possibly transplant rejection in kidney transplant (KT) patients. This study was conducted to investigate the incidence and risk factors of CMV disease in kidney transplant patients. Methods: All end-stage renal disease (ESRD) patients who underwent kidney transplantation during 1998-2014 and their donors were assessed...
متن کاملPrevalence of herpes simplex virus type 1 and 2 infections in renal transplant recipients and their renal function
Background and Objectives: Viral infections are a major problem for transplant recipients. Reactivation of viruses is associated with the use of strong immunosuppressive drugs. Herpes simplex virus infections in renal transplant patients may become severe without treatment. Although the prevalence and role of herpes simplex viruses 1 and 2 in bone marrow and lung recipients are well known; howe...
متن کاملComparison of Serum Cystatin C and Creati-nine Levels to Evaluate Early Renal Function after Kidney Transplantation
Background: Accurate and rapid assessment of allograft function is essential in renal transplant recipients in order to detect allograft rejection and to monitor drug nephrotoxicity. We aimed to evaluate the usefulness of cystatin C as a marker of kidney allograft function in the early post-transplant period and to compare this value with that of conventional serum creatinine concentration. Met...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 38 3 شماره
صفحات -
تاریخ انتشار 2000