Reliability of Stereotactic Coordinates of 1.5-Tesla and 3-Tesla MRI in Radiosurgery and Functional Neurosurgery
نویسندگان
چکیده
OBJECTIVE The aims of this study are to identify interpersonal differences in defining coordinates and to figure out the degree of distortion of the MRI and compare the accuracy between CT, 1.5-tesla (T) and 3.0T MRI. METHODS We compared coordinates in the CT images defined by 2 neurosurgeons. We also calculated the errors of 1.5T MRI and those of 3.0T. We compared the errors of the 1.5T with those of the 3.0T. In addition, we compared the errors in each sequence and in each axis. RESULTS The mean difference in the CT images between the two neurosurgeons was 0.48±0.22 mm. The mean errors of the 1.5T were 1.55±0.48 mm (T1), 0.75±0.38 (T2), and 1.07±0.57 (FLAIR) and those of the 3.0T were 2.35±0.53 (T1), 2.18±0.76 (T2), and 2.16±0.77 (FLAIR). The smallest mean errors out of all the axes were in the x axis : 0.28-0.34 (1.5T) and 0.31-0.52 (3.0T). The smallest errors out of all the MRI sequences were in the T2 : 0.29-0.58 (1.5T) and 0.31-1.85 (3.0T). CONCLUSION There was no interpersonal difference in running the Gamma Plan® to define coordinates. The errors of the 3.0T were greater than those of the 1.5T, and these errors were not of an acceptable level. The x coordinate error was the smallest and the z coordinate error was the greatest regardless of the MRI sequence. The T2 sequence was the most accurate sequence.
منابع مشابه
Actualities and Perspectives in Neurosurgery
In the field of neurosurgery, like in other surgical specialties, the last decades have brought major achievements. The series of revolutionary discoveries has started during the last century in the fifties, with stereotactic radiosurgery, then continued with the implementation of operative microscope (during the seventies), the endovascular embolisation in the nineties and finally with the maj...
متن کاملDesign, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems
Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...
متن کاملMRI changes in the rat hippocampus following proton radiosurgery.
PURPOSE To define radiographic dose-response relationships for proton radiosurgery using a rat brain model. METHODS AND MATERIALS A group of 23 rats was treated with Bragg peak proton beam irradiation involving the right hippocampus. Single doses of 5, 12, 20, 30, 60, 90 and 130 cobalt gray equivalents (CGE) were delivered to groups of 3 animals using single fraction technique. One extra anim...
متن کاملMagnetic resonance imaging of implanted deep brain stimulators: experience in a large series.
Magnetic resonance imaging (MRI) is a commonly used and important imaging modality to evaluate lead location and rule out complications after deep brain stimulation (DBS) surgery. Recent safety concerns have prompted new safety recommendations for the use of MRI in these patients, including a new recommendation to limit the specific absorption rate (SAR) of the MRI sequences used to less than 0...
متن کاملEvaluation of MRI-based MAGIC polymer gel dosimeter in small photon fields
Background: Accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (SRS) and intensity modulated radiotherapy (IMRT). Precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. In the p...
متن کامل