A Custom-made Acetabular Implant for Paprosky Type 3 Defects.
نویسندگان
چکیده
Acetabular revision is a challenging operation, especially when dealing with major bone loss and poor bone quality. This article describes a detailed approach to defect analysis, including measurement of bone deficiency and bone quality. A custom-made titanium implant, with precisely outlined flanges to the host bones of the ilium, ischium, and pubis, taking into account the bone quality for optimal screw purchase, was used to reconstruct the acetabular defect. Preliminary results for 12 patients who were retrospectively reviewed after a minimum follow-up of 18 months were promising. [Orthopedics. 2017; 40(1):e195-e198.].
منابع مشابه
Managing bone loss in acetabular revision.
The management of bone loss encountered during acetabular revision remains challenging. In order to obtain a successful surgical result, preoperative planning is required to estimate the severity and location of bone defects. Most acetabular revisions can be treated with the use of a cementless hemispherical component. However, a successful surgical reconstruction requires component stability. ...
متن کاملHigh complication rate in reconstruction of Paprosky type IIIa acetabular defects using an oblong implant with modular side plates and a hook.
We report the results of 62 hips in 62 patients (17 males, 45 females) with mean age of 62.4 years (37 to 81), who underwent revision of the acetabular component of a total hip replacement due to aseptic loosening between May 2003 and November 2007. All hips had a Paprosky type IIIa acetabular defect. Acetabular revision was undertaken using a Procotyl E cementless oblong implant with modular s...
متن کاملRevision Total Hip Arthroplasty Using Tantalum Augment in Patients with Paprosky III or IV Acetabular Bone Defects: A Minimum 2-year Follow Up Study
PURPOSE The purpose of this study is to report the short-term outcomes of revision total hip arthroplasty (THA) using tantalum augments in patients with severe acetabular bone defects. MATERIALS AND METHODS We retrospectively analyzed 15 revision THAs performed in 15 patients using tantalum augments between June 2010 and December 2013. Acetabular bone defects were Paprosky type IIIA in 7 hips...
متن کاملThe Long Oblique Revision component in revision arthroplasty of the hip.
Migration of the acetabular component may give rise to oval-shaped bone defects in the acetabulum. The oblong implant is designed to fill these defects and achieve a stable cementless anchorage with no significant bone loss. We prospectively reviewed 133 oblong long oblique revision components at a mean follow-up of 9.74 years (0.6 to 14). All had been used in revisions for defects of type IIB ...
متن کاملStructural and Morselized Allografting Combined with a Cementless Cup for Acetabular Defects in Revision Total Hip Arthroplasty: A 4- to 14-Year Follow-Up
Using morselized and structural allograft to restore bone stock for massive acetabular bone defect in revision total hip arthroplasty (THA) is an appealing procedure. However, concerns about inability to achieve long-term stability following allograft resorption remained. From 2003 to 2012, 59 hips in 58 patients undergoing revision THA for Paprosky type II or III acetabular defects were retros...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 40 1 شماره
صفحات -
تاریخ انتشار 2017