Astigmatism management in cataract surgery with Precizon® toric intraocular lens: a prospective study

نویسندگان

  • Carolina Vale
  • Carlos Menezes
  • J Firmino-Machado
  • Pedro Rodrigues
  • Miguel Lume
  • Paula Tenedório
  • Pedro Menéres
  • Maria do Céu Brochado
چکیده

PURPOSE The purpose of this study was to evaluate the visual and refractive outcomes and rotational stability of the new aspheric Precizon(®) toric intraocular lens (IOL) for the correction of corneal astigmatism in cataract surgery. SETTING Department of Ophthalmology, Hospital Geral de Santo António - Centro Hospitalar do Porto, EPE and Hospital de Pedro Hispano, Matosinhos, Portugal. DESIGN This was a prospective clinical study. PATIENTS AND METHODS A total of 40 eyes of 27 patients with corneal astigmatism greater than 1.0 diopter (D) underwent cataract surgery with implantation of Precizon(®) toric IOL. IOL power calculation was performed using optical coherence biometry (IOLMaster(®)). Outcomes of uncorrected (UDVA) and best-spectacle corrected distance visual acuities (BCDVA), refraction, and IOL rotation were analyzed at the 1st week, 1st, 3rd, and 6th month's evaluations. RESULTS The median postoperative UDVA was better than preoperative best-spectacle corrected distance visual acuity (0.02 [0.06] logMAR vs 0.19 [0.20] logMAR, P<0.001). At 6 months, postoperative UDVA was 0.1 logMAR or better in 95% of the eyes. At last follow-up, the mean spherical equivalent was reduced from -3.35±3.10 D to -0.02±0.30 D (P<0.001) with 97.5% of the eyes within ±0.50 D of emmetropia. The mean preoperative keratometric cylinder was 2.34±0.95 D and the mean postoperative refractive cylinder was 0.24±0.27 D (P<0.001). The mean IOL rotation was 2.43°±1.55°. None of the IOLs required realignment. CONCLUSION Precizon(®) toric IOL revealed very good rotational stability and performance regarding predictability, efficacy, and safety in the correction of preexisting regular corneal astigmatism associated with cataract surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Outcomes After Cataract Surgery With a New Transitional Toric Intraocular Lens.

PURPOSE To evaluate the visual outcomes of patients who underwent cataract surgery with implantation of a transitional toric monofocal intraocular lens (IOL) (Precizon Toric IOL, model 565; Ophtec BV, Groningen, The Netherlands). METHODS In this prospective case series, 51 eyes of 39 patients with cataract and regular keratometric astigmatism between 1.00 and 4.50 diopters (D) that had phacoe...

متن کامل

Toric intraocular lens implantation for astigmatism correction in cataract surgery.

The aim of this study was to evaluate clinical outcomes after toric intraocular lens implantation for astigmatism correction in patients undergoing cataract surgery. This prospective observational study included eyes undergoing cataract surgery at Sestre milosrdnice University Hospital Center between February and September 2011. The study enrolled eyes that had visually significant cataract and...

متن کامل

Surgical management of astigmatism with toric intraocular lenses.

Correction of corneal astigmatism is a key element of cataract surgery, since post-surgical residual astigmatism can compromise the patient's uncorrected visual acuity. Toric intraocular lenses (IOLs) compensate for corneal astigmatism at the time of surgery, correcting ocular astigmatism. They are a predictable treatment. However, accurate measurement of corneal astigmatism is mandatory for ch...

متن کامل

Results of the AcrySof Toric intraocular lenses implantation

BACKGROUND The expectations of post-removal cataract surgery patients are extremely high, and best vision acuity is expected. The best refractive results are influenced by two factors - cataract surgical removal and the corneal astigmatism correction. Currently, the two most often applied corneal astigmatism removal methods are laser surgery and toric intraocular lens implantation, with the lat...

متن کامل

Foldable toric intraocular lens for astigmatism correction in cataract patients.

PURPOSE To evaluate the results of AcrySof toric intraocular lens (IOL) (Alcon) implantation to correct preexisting astigmatism in patients having cataract surgery. SETTING Ophthalmology Service, Donostia Hospital, San Sebastián, Spain. METHODS This prospective observational study included 30 eyes of 15 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016