Biocompatibility and magnetic resonance imaging characteristics of carbon nanotube yarn neural electrodes in a rat model

نویسندگان

  • Yi Guo
  • Wanru Duan
  • Chao Ma
  • Changqing Jiang
  • Yikuan Xie
  • Hongwei Hao
  • Renzhi Wang
  • Luming Li
چکیده

BACKGROUND Implantation of deep brain stimulation (DBS) electrodes is a landmark therapy for movement disorders and some mental conditions. Compared to conventional platinum-iridium (Pt-Ir) electrodes, carbon nanotube yarns (CNTY) electrodes have improved stability and interface characteristics with less distortion during high field strength MRI. Sprague-Dawley rat models were used to examine thein vivo histological and imaging properties of biocompatible CNTY throughout the subacute period. METHODS Sprague-Dawley rats received CNTY (n = 16) or Pt-Ir control (n = 16) electrodes. Behavioral markers, body weight, and survival were recorded. Comparative histology (HE, NeuN, CD68, and GFAP) was performed at 1, 6, and 12 weeks post-implantation; 3.0T MRI was performed at 1 and 12 weeks. RESULTS Of 32 rats, 30 (15 per group) survived implantation without reduced activity, paralysis, or incapacity to feed. Following implantation, progressive decreases in macrophage activation and neuron-depleted margins surrounding electrodes were observed in both groups. Inflammatory marker expression (CD68) was significantly lower in rats with implanted CNTY electrodes compared to controls at all time points. CNTY electrodes also caused less inflammation and shallower depths of macrophage penetration and neural disruption relative to the interface. Artifacts and distortion were observed on MRI of Pt-Ir but not CNTY electrodes. CONCLUSIONS CNTY electrodes exhibited reduced inflammatory margins compared to Pt-Ir electrodes throughout the subacute period, indicating reduced initial trauma, better overall biocompatibility, and reduced fibrous tissue formation. Coupled with less MRI distortion, CNTY electrodes may be useful alternatives when there is a need to monitor electrode placement by MRI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carbon Nano-Structured Neural Probes Show Promise for Magnetic Resonance Imaging Applications.

Objective Previous animal studies have demonstrated that carbon nanotube (CNT) electrodes provide several advantages of preferential cell growth and better signal-to-noise ratio when interfacing with brain neural tissue. This work explores another advantage of CNT electrodes, namely their MRI compatibility. MRI-compatible neural electrodes that do not produce image artifacts will allow simultan...

متن کامل

ANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST

Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...

متن کامل

Improvement of system capacitance via weavable superelastic biscrolled yarn supercapacitors

Yarn-based supercapacitors having improved performance are needed for existing and emerging wearable applications. Here, we report weavable carbon nanotube yarn supercapacitors having high performance because of high loadings of rapidly accessible charge storage particles (above 90 wt% MnO2). The yarn electrodes are made by a biscrolling process that traps host MnO2 nanoparticles within the gal...

متن کامل

A model for modified electrode with carbon nanotube composites using percolation theory in fractal space

We introduce a model for prediction the behavior of electrodes which modified withcarbon nanotubes in a polymer medium. These kinds of polymer composites aredeveloped in recent years, and experimental data for its percolation threshold isavailable. We construct a model based on percolation theory and fractal dimensionsand using experimental percolation threshold for calculating the moments of c...

متن کامل

Static Coil Design Considerations for the Magnetic Resonance Imaging

One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2015