Determination of intralumenal individual bile acids by HPLC with charged aerosol detection.
نویسندگان
چکیده
An isocratic HPLC charged aerosol detector (CAD) method was developed, validated, and applied for the determination of individual bile acids in human gastric and duodenal aspirates. The method requires a low volume of aspirates (50-100 microl) and minimal sample pretreatment. A Hypersil BDS RP-C(18) column (250 x 4.6 mm, 5 microm particle size) was equilibrated with a mobile phase composed of methanol-[ammoniun formate 20 mM, formic acid 0.5%, triethylamine 0.2% (pH 3)] 67:33 v/v. Its flow rate was 1 ml/min. The elution times for taurocholate, glycocholate, taurochenodeoxycholate, ursodeoxycholate, glycochenodeoxycholate, cholate, and glycodeoxycholate were approximately 9.9, 16.2, 18.2, 21.3, 31.6, 34.5, and 38.5 min, respectively. Calibration curves in the mobile phase were constructed in the concentration range of 0.5-500 microM. Limits of detection and quantification were in the range of 0.07-0.60 microM and 0.20-1.80 microM, respectively. This method was applied first, in gastric aspirates collected in the fasted state, in which bile acid presence is minimal and, second, in duodenal aspirates collected in the fed state, in which a large number of potentially interfering compounds exists. Intra-day relative standard deviation in fasted gastric aspirates and in fed duodenal aspirates was less than 2.2% and 6.0%, respectively.
منابع مشابه
Determination of Olive Oil Adulteration by Principal Component Analysis with HPLC–Charged Aerosol Detector Data
Overview Purpose: To examine the use of targeted principal component analysis (PCA) with HPLC-charged aerosol detector data as a means of determining adulteration of olive oils. Method: Oil samples were analyzed as both untreated and hydrolyzed, using a C30 HPLC method and charged aerosol detection. PCA results were determined using peak area percent values of the acylglycerides and free fatty ...
متن کاملSimple Separation and Detection Techniques for the Analysis of Carbohydrates
Carbohydrates are diffi cult to analyze because they are very polar compounds, exhibit similar structural characteristics, and do not have a suitable chromophore. Their analysis is often performed directly using high-performance anion-exchange chromatography with pulsed amperometric detection (HPAE-PAD) with a high pH mobile phase. This technique has been approved for use in a variety of offi c...
متن کاملDetermination of Carboxylic Acids in Apple Juice by RP HPLC
Low molecular weight organic acids are most predominant in apple juice among these components fumaric acid was not exceed more than 5 ppm. It was thought that the HPLC is the best method of the determination of organic acids in the apple juice. In this study, chromatographic separation of organic acids of apple juice was obtained by preparing a sample and by applying them to acid phase for ...
متن کاملAnalysis of Phospholipids in Natural Samples by Normal Phase HPLC and Corona Charged Aerosol Detection
متن کامل
Development of a New Universal HPLC Detector: The Corona CAD
Recently, a new universal HPLC detection technology has been developed based on charged aerosol detection that has led to the development of a universal HPLC detector, the Corona CAD. To further understand the capabilities of charged aerosol detection and the use of the technology in an HPLC detector, the Corona CAD was tested for its sensitivity, dynamic range, response from compounds of diffe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of lipid research
دوره 49 12 شماره
صفحات -
تاریخ انتشار 2008